一种创新的基于传输电子显微镜的超结构成像方法,用于诊断呼吸道状腺疾病
Shikha Chaudhary1, Kana Ram Jat2, Subhash Chandra Yadav1
1Electron Microscope Facility, Department of Anatomy, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, Delhi 110029, India.
概括
这项研究通过优化样本采集和超结构分析来增强传输电子显微镜用于诊断状动脉疾病. 改进的方法显著提高了诊断准确性,如初级状动力障碍等疾病.
科学领域:
- 生物医学成像技术 生物医学成像技术
- 细胞生物学 细胞生物学
- 诊断病理学的诊断病理学
背景情况:
- 传输电子显微镜 (TEM) 对于诊断状腺疾病至关重要.
- 目前的TEM方法面临的挑战是由于样本异质性,低细胞产量和不适当的固定.
- 实现最佳状超结构的困难阻碍了准确的诊断.
研究的目的:
- 优化对TEM的样本采集和准备技术.
- 为了提高诊断状超结构的产量和质量.
- 为了提高使用TEM的状动脉疾病的诊断准确度.
主要方法:
- 优化鼻腔样本采集,包括预清洗,多次刷子更换和配对采集.
- 改进了初级固定协议,以保护状超结构.
- 经过修改的超切割与样本倾斜 (α轴±40°,β轴±25°) 以提高眼的可见性.
主要成果:
- 在上皮质细胞产量上达到32倍的增长.
- 获得了大约20倍多的可报告的毛超结构 (例如,9+2模式,dynein臂).
- 在135/200名患者中,状动脉疾病的诊断准确度从5%提高到67%.
结论:
- 优化的TEM协议显著改善了对状动脉疾病的诊断产量.
- 这种增强的常规方法的准确性与先进的冷电子断层扫描相提并论.
- 这种精细的方法提供了一种更可靠的方法来诊断原发性纤毛功能障碍和相关疾病.
相关概念视频
Overview of Electron Microscopy
8.4K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
8.4K
Electron Microscope Tomography and Single-particle Reconstruction
2.3K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.3K
Transmission Electron Microscopy
5.3K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
5.3K
Immunogold Electron Microscopy
3.9K
Immunoelectron microscopy utilizes immunogold labeling of endogenous proteins with specific antibodies to detect and localize these proteins in cells and tissues. The procedure provides insights into the distribution and quantification of protein under different stimulation conditions offering clues about their functions. Conjugating highly electron-dense gold particles with primary or secondary antibodies allow antigen detection on and within cells, with high resolution and specificity.
3.9K
Studying the Cytoskeleton
5.7K
The cytoskeletal architecture can be studied using different microscopic and biochemical techniques. Electron microscopy was instrumental in discovering the cytoskeletal architecture around the 1960s, which allowed obtaining structural information at a high-resolution level. However, the sample preparation procedure often limits this ability in biological samples. Several protocols have been developed over the years to optimize sample preparation. In one of the protocols known as rotary...
5.7K
Cryo-electron Microscopy
3.2K
Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
3.2K