调查Apple WatchVO2max测量的准确性:一个验证研究
Rory Lambe1,2, Ben O'Grady1,2, Maximus Baldwin1,2,3
1School of Public Health, Physiotherapy and Sports Science, University College Dublin, Dublin 4, Ireland.
PloS one
|May 15, 2025
概括
与间接热量计相比,Apple Watch低估了VO2max,这是一个关键的健康指标. 虽然尚未在临床上得到验证,但其用于心肺健康的实际用途需要进一步研究.
科学领域:
- 评估心肺呼吸系统的健康状况
- 穿戴式技术验证可穿戴技术验证
- 临床诊断 临床诊断 临床诊断
背景情况:
- VO2max是心肺健康和整体健康的关键指标.
- 更高的心肺呼吸能力与心血管疾病,糖尿病和癌症的风险降低有关.
- 间接热量计是VO2最大值测量的黄金标准,但它资源密集.
研究的目的:
- 为了评估Apple Watch产生的VO2最大估计的准确性和有效性.
- 为了比较Apple Watch的VO2max测量与间接热量计的黄金标准方法.
主要方法:
- 30名参与者佩戴果手表5-10天,以获得VO2最大估计值.
- 然后,参与者使用修改的奥斯特兰德协议完成了最大运动跑步机测试.
- 使用布兰德-阿尔特曼分析,平均绝对百分比误差 (MAPE) 和平均绝对误差 (MAE) 分析了协议.
主要成果:
- 果手表显示VO2max的低估,平均差异为6.07毫升/千克/分钟.
- 协议的极限显示了果手表和间接热量计方法之间的相当大的变化.
- MAPE为13.31%,MAE为6.92毫升/公斤/分钟,这表明测量有重大误差.
结论:
- 果手表VO2max估计需要进一步细化,以获得可靠的临床应用.
- 尽管精度有限,但Apple Watch的实用实用性可能使其成为基于运动的VO2max预测的可行替代品.
相关概念视频
Measurement of Blood Pressure
703
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
703
Special considerations while measuring blood pressure
692
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
692
Assessment of blood pressure in brachial artery(two-step method)
632
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
632
Errors occurring during blood pressure monitoring
573
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
573
Equipments Used To Measure Blood Pressure
768
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
768
Testing a Claim about Standard Deviation
2.4K
A complete procedure to test a claim about population standard deviation or population variance is explained here.
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
2.4K