基于二次侧面直接系列拓的分布式无线电力传输,用于与建筑附带的光伏系统集成
Zhecheng Zhang1, Hao Chen1, Wanying Weng1
1College of Electrical Engineering, Zhejiang University, Hangzhou, China.
Scientific reports
|May 15, 2025
概括
本研究介绍了一种具有成本效益的,灵活的分布式无线电力传输 (WPT) 系统,用于建筑附带光伏 (BAPV) 应用. 新的设计提高了BAPV集成的效率和稳定性.
科学领域:
- 可再生能源系统可再生能源系统
- 电气工程 电气工程
- 可持续建筑技术 可持续建筑技术
背景情况:
- 建筑附带光伏 (BAPV) 系统对于环保目标至关重要.
- 在BAPV系统中,无线电力传输 (WPT) 在平衡成本,效率和灵活性方面面临挑战.
- 现有的分布式WPT系统需要二次整流器,增加成本和复杂性.
研究的目的:
- 为BAPV应用提供一种新的分布式无线电力传输 (WPT) 系统.
- 通过使用二次侧向直连 (SSDS) 拓学,通过消除二次整流器来降低成本和尺寸.
- 通过集成的线圈设计和新的同步策略来提高效率,稳定性和同步精度.
主要方法:
- 为分布式WPT.实施二次侧面直接系列 (SSDS) 拓.
- 开发一个平面的,用于使用PCB电线的功率和检测线圈的综合设计.
- 引入基于检测线圈的同步策略,以确保系统稳定性和安全性.
主要成果:
- 拟议的SSDS分布式WPT系统与传统系统相比,大大降低了成本和尺寸.
- 集成线圈设计提高了一致性,同步精度和效率.
- 一个850W原型的实验验证实现了超过85%的效率.
结论:
- 开发的SSDS分布式WPT系统为BAPV集成提供了具有成本效益,高效和灵活的解决方案.
- 新的设计和同步策略确保了稳定和安全的运行.
- 这项技术促进了可再生能源在建筑物中的整合.
更多相关视频
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
156
11:26Integrating a Triplet-triplet Annihilation Up-conversion System to Enhance Dye-sensitized Solar Cell Response to Sub-bandgap Light
Published on: September 12, 2014
12.5K
相关概念视频
Secondary Distribution
74
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
74
Maximum Power Transfer
190
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
190
P-N junction
417
A p-n junction is formed when p-type and n-type semiconductor materials are joined together. At the interface of the p-n junction, holes from the p-side and electrons from the n-side begin to diffuse into the opposite sides due to the concentration gradient. This diffusion of carriers leads to a region around the junction where there are no free charge carriers, known as the depletion region. The charge density within the depletion region for the n-side and p-side can be described by the...
417
Power System Distribution
219
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
219
Induced Electric Fields: Applications
1.5K
An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
1.5K
The Power Superposition Principle
138
Consider a circuit with two sinusoidal voltage sources. Each one influences the circuit independently, and the superposition principle helps us understand the combined effect by adding up the responses from each source.
138