基于OCPP-P2G-CHP合运行的综合能源系统的低碳经济调度
Jingjing Ma1, Wentao Huang1, Can Lv1
1Hubei Key Laboratory for High-Efficiency Utilization of Solar Energy and Operation Control of Energy Storage System, Hubei University of Technology, Wuhan, China.
PloS one
|May 19, 2025
概括
本研究介绍了一种综合能源系统模型,其中包括富含氧的燃烧发电厂 (OCPP),电气化发电厂 (P2G) 和热电联合发电 (CHP) 以减少排放. 这种创新系统大大降低了成本和碳排放量,支持了节能目标.
科学领域:
- 能源系统工程 能源系统工程
- 环境科学 环境科学
- 化学工程是化学工程的重要组成部分.
背景情况:
- "双碳"倡议需要创新的节能和减排战略.
- 传统的能源系统在满足严格的环境目标方面面临挑战.
研究的目的:
- 为一个综合能源系统 (IES) 开发一个低碳经济调度模型.
- 优化运营支出,同时提高碳捕获和减少排放.
主要方法:
- 为IES构建了一个低碳经济调度模型,其中包括富含氧的燃烧发电厂 (OCPP),两级电气化发电 (P2G) 和热电联产 (CHP) 装置.
- 整合了需求响应 (DR) 机制,并为OCPP,P2G和CHP系统开发了数学模型.
- 将传统的热能发电机组转换为OCPP.
主要成果:
- 与传统系统相比,OCPP-P2G-CHP集成系统的碳捕获效率得到了提高.
- 实现了7.8%的总体运营成本降低.
- 减少了30.2%的碳排放.
结论:
- 拟议的综合能源系统模型对工业和城市能源网络具有可行性和创新性.
- 该模型有效地平衡了经济调度与环境目标.
- 支持可扩展的应用,以实现"双碳"目标.
相关概念视频
Maximum Power Flow and Line Loadability
91
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
91
Fast Decoupled and DC Powerflow
148
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
148
Power System Distribution
224
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
224
Energy Line and Hydraulic Gradient Line
595
Based on Bernoulli's equation, the energy line (EL) and hydraulic grade line (HGL) provide graphical representations of energy distribution in a fluid flow system. For steady, incompressible, inviscid flows, Bernoulli's equation is expressed as:
595
Load-frequency control
112
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
112
Power Factor Correction
150
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
150