在现场使用仪器口罩测量头部加速暴露量:用于完整暴露分析的缺失数据归算
David Luke1,2, Zaryan Masood1, Daniel Bondi2
1Department of Mechanical Engineering, University of British Columbia, Vancouver, BC, Canada.
Annals of biomedical engineering
|May 21, 2025
概括
本研究介绍了估计冰球中缺失的头部加速事件 (HAE) 数据的方法,揭示了运动员暴露和脑损伤风险指标的严重低估.
科学领域:
- 运动医学 运动医学
- 生物力学 生物力学
- 神经学 神经学
背景情况:
- 精确量化头部加速事件 (HAE) 对于了解接触运动中脑损伤风险至关重要.
- 缺少HAE数据是现实世界体育研究中的一个常见挑战.
- 现有的方法可能无法完全捕捉运动员经历的头部冲击程度.
研究的目的:
- 开发和应用缺失数据归算方法来估计完全头部加速事件 (HAE) 暴露.
- 量化缺失数据对大学男子冰球HAE暴露指标的影响.
- 为了提高HAE暴露数据的准确性,用于脑损伤风险评估.
主要方法:
- 在一个大学曲棍球赛季中收集了HAE的视频和仪器口罩 (iMG) 数据.
- 使用统计映射技术从有限的摄像头角度计算出缺失的基于视频的HAE.
- 应用多重归算来估计基于iMG的缺失HAE,使用完整的视频数据.
主要成果:
- 45%的运动员游戏缺乏记录的iMG数据.
- 数据归算增加了每个运动员季节的中位数HAE数量10% (视频) 和69% (iMG).
- 累积暴露指标,包括峰值线性/角加速和体应变,在计量后显著增加.
结论:
- 缺少HAE数据导致运动员暴露和相关脑创伤风险的大幅低估.
- 计量方法对于在体育研究中准确评估HAE暴露至关重要.
- 这项研究为未来关于急性和长期脑损伤风险的研究提供了关键的基础.
更多相关视频
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
2.1K
07:32Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
989
相关概念视频
Mass Analyzers: Overview
2.1K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
2.1K
Tandem Mass Spectrometry
3.0K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
3.0K
Atomic Absorption Spectroscopy: Lab
1.3K
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
1.3K