(Y-Knot RC®) vs

Dalos Dimitris1, Grisolia Seifert Eric2, Fiedler Imke2

  • 1UKE Athleticum - Center for Athletic Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, Germany; Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.

概括

为了获得最佳的生物机械性能,全接 (ASA) 需要距离皮质-形接口至少4mm的距离. 插入深度没有影响拉出强度,但增加了结构刚性.