基于大小准备的MR-声波辐射力成像成像
Anuj Sharma1, Kristen Zarcone1, William A Grissom1
1Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
Magnetic resonance in medicine
|May 30, 2025
概括
幅度对比MR声波辐射力成像 (Mag-ARFI) 可视化超声波焦点没有相减法,减少运动工件. 这种方法融合了解剖学和焦点描绘,以获得更清晰的成像.
科学领域:
- 医疗成像医学成像
- 声波辐射力成像 声波辐射力成像
- 磁共振成像是一种磁共振成像技术.
背景情况:
- 传统相位对比-ARFI对运动和呼吸器件敏感.
- 同时可视化超声波焦点和解剖是具有挑战性的.
研究的目的:
- 在没有相减法的情况下可视化组织中的超声波焦点,减少运动和呼吸灵敏度.
- 为了在各种图像对比度中实现解剖学和超声波焦点的融合描绘.
主要方法:
- 实施了大小对比MR声波辐射力成像 (Mag-ARFI) 序列.
- 转换的位移诱导的相位转移到调制的纵向磁化.
- 在幻影和体内实验中,将Mag-ARFI与常规相差-ARFI进行比较,包括模拟呼吸运动的头部成像.
主要成果:
- 在位移量化 (R=0.88) 方面,mag-ARFI与相对比ARFI有很强的一致性.
- 磁ARFI图像融合了焦点和背景解剖学,与相对比ARFI相对比很好 (T1加权的R=0.87,T2加权的R=0.79).
- 马格-ARFI显示呼吸运动器件显著减少 (3.5x更低的变化系数).
结论:
- 磁ARFI使超声波的焦点定位具有减少运动的文物.
- 这种技术为T1和T2加权大小图像提供了融合的解剖和焦点信息.
相关概念视频
Magnetic Resonance Imaging
7.3K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
7.3K
Atomic Nuclei: Magnetic Resonance
766
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
766
Atomic Force Microscopy
3.6K
Atomic force microscopy (AFM) is a type of scanning probe microscopy that can analyze topographic details of various specimens like ceramics, glass, polymers, and biological samples. AFM offers over 1000 times more resolution than the optical imaging system. Images generated from AFM are three-dimensional surface profiles, offering an advantage over the flat, two-dimensional images from other imaging techniques.
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
3.6K
NMR Spectrometers: Resolution and Error Correction
784
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
784


