一种无维度的方法,以最大限度地减少单通反透淡化系统的能源消耗
Muhammad H Elbassoussi1, Omar G Kaoud1, Syed M Zubair2
1Department of Mechanical Engineering, King Fahd University of Petroleum & Minerals (KFUPM), Dhahran, Saudi Arabia.
Water research
|May 31, 2025
概括
优化单通多膜反透 (RO) 淡化利用新的无维指数. 该研究揭示了膜参数分布策略显著影响基于料盐度和系统大小的能源效率.
科学领域:
- 水处理技术水处理技术.
- 化学工程原理 化学工程原理
- 可持续能源解决方案 可持续能源解决方案
背景情况:
- 反透 (RO) 对于海水淡化至关重要,但能源密集型.
- 优化多膜系统需要了解参数相互作用.
- 现有的模型往往缺乏无维的框架,以实现广泛的适用性.
研究的目的:
- 开发一种无维度的方法来优化单通多膜RO的能源效率.
- 为系统可行性引入新的无维性能指数 (RRI和PSI).
- 确定和优化对能源消耗最有影响的无维膜参数 (Sa*).
主要方法:
- 引入恢复比率指数 (RRI) 和透盐度指数 (PSI).
- 灵敏度分析以确定影响特定能耗 (Sa*) 的关键参数.
- 在均和不均 (下降/上升) 分布下,Sa*的优化.
- 探索系统大小和料盐度对最佳Sa*形状的影响.
主要成果:
- 无维膜参数 (Sa*) 显著影响能源消耗.
- 下降的Sa*档案提高了低盐度料的早期恢复和效率.
- 上升的Sa*配置文件减轻了透压力,并提高了高盐度料的性能.
- 最佳的Sa*分配策略取决于系统大小和料盐度.
结论:
- 无维度指数 (RRI,PSI) 为RO系统设计提供了一个强大的框架.
- 量身定制的Sa*分配策略 (下降/上升) 提供了显著的能源节约.
- 结果为优化单通多膜RO配置提供了实用指南.
更多相关视频
09:39Proof-of-Concept for Gas-Entrapping Membranes Derived from Water-Loving SiO2/Si/SiO2 Wafers for Green Desalination
Published on: March 1, 2020
7.5K
10:19Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
11.5K
相关概念视频
Osmosis and Osmotic Pressure of Solutions
41.6K
A number of natural and synthetic materials exhibit selective permeation, meaning that only molecules or ions of a certain size, shape, polarity, charge, and so forth, are capable of passing through (permeating) the material. Biological cell membranes provide elegant examples of selective permeation in nature, while dialysis tubing used to remove metabolic wastes from blood is a more simplistic technological example. Regardless of how they may be fabricated, these materials are generally...
41.6K
Application of the Energy Equation
1.1K
The application of the energy equation to centrifugal pumps is a fundamental principle in fluid dynamics and engineering. In this scenario, the energy equation is used to calculate the flow rate of a centrifugal pump responsible for transferring water between two reservoirs at different elevations. The pump applies an energy input of 7500 joules per second, and the vertical difference between the lower and upper reservoirs is 10 meters. Additionally, the head loss due to friction and other...
1.1K
Energy Considerations in Open Channel Flow
178
Open channel flow, where a fluid flows with a free surface exposed to the atmosphere, is primarily governed by gravitational and surface effects, distinguishing it from closed conduit or pipe flow. In open channels such as rivers, canals, and artificial channels, energy analysis provides valuable insights into flow behavior and the relationship between depth, velocity, and slope.Specific Energy and Flow DepthIn open channel flow, the specific energy, E, combines the gravitational potential...
178
Osmosis
7.9K
Osmosis is the movement of free water molecules through a semipermeable membrane. The water's concentration gradient across the membrane is inversely proportional to the solutes' concentration. Whereas diffusion transports material across membranes and within cells, osmosis transports only water across a membrane, and the membrane limits the diffusion of solutes in the water. Osmosis is a special case of diffusion.
Water, like other substances, moves from a high concentration of...
Water, like other substances, moves from a high concentration of...
7.9K
Conservation of Energy in Control Volume
915
Consider a turbine operating under steady-flow conditions. The control volume is drawn around the turbine, with fluid entering at one point and exiting at another. The turbine extracts energy from the fluid, which performs mechanical work (shaft work).
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
915
Fast Decoupled and DC Powerflow
303
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
303