在联合轴向和侧向负载下倾斜式固体和复合材料绝缘墙面板的数据集
Salam Al-Rubaye1, Marc Maguire1
1Durham School of Architectural Engineering and Construction, University of Nebraska-Lincoln, 1110 S. 67th St., Omaha, NE 68182, United States.
Data in brief
|June 9, 2025
概括
这项研究评估了混凝土隔热墙面板 (CIP) 和传统的向上倾斜面板,评估连接器性能和结构行为. 这些发现为工程师和对隔热墙系统的研究人员提供了宝贵的数据.
科学领域:
- 结构工程 结构工程
- 材料科学 材料科学 材料科学
- 建筑技术 建筑技术 建筑技术
背景情况:
- 传统的倾斜板具有有限的可用数据.
- 对隔热墙系统缺乏全面的数据集.
- 了解面板连接器的性能对于结构完整性至关重要.
研究的目的:
- 为了研究各种剪切连接器的混凝土绝缘墙面板 (CIP) 的曲行为.
- 通过双重剪切测试来评估 wythe 连接器的剪切性能.
- 为结构工程师,代码委员会和研究人员提供有价值的数据集.
主要方法:
- 在六个传统的倾斜板和17个CIP上进行了大规模测试.
- 在Wythe连接器上进行了30次双剪切测试.
- 收集了详细的样本描述和测试输出数据.
主要成果:
- 该数据集提供了对CIP在侧向和轴向负载组合下性能的关键见解.
- 评估了不同连接器的剪切性能.
- 建立了对绝缘和传统倾斜墙系统的综合数据集.
结论:
- 生成的数据集填补了对隔热墙系统的文献中的重大空白.
- 这些数据对结构工程师,代码开发和数值建模非常有价值.
- 这项研究增强了对现代混凝土墙系统性能的理解.
相关概念视频
Posttensioned Masonry Walls
129
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
129
Masonry Loadbearing Walls
102
Masonry load-bearing walls, constructed from materials like brick, stone, or concrete masonry units, serve as a crucial component in building structures by supporting the loads from floors and roofs and transferring them to the foundation. These walls, known for their compressive strength, can be reinforced or unreinforced to suit different building needs, accommodating both the dead and live loads while maintaining safety through lower working stresses compared to the materials' ultimate...
102
Composite Masonry Walls
1.1K
Composite masonry walls combine multiple wythes of the same or different masonry materials to create a unified structure. These walls feature wythes that are bonded together either through mortar-filled collar joints, grouted spaces, or more commonly, with rigid metal ties and reinforcements, with the use of masonry header units being rare. Metal ties are preferred because they effectively minimize water penetration, as these walls primarily absorb moisture and then release it into the...
1.1K
Unsymmetric Loading of Thin-Walled Members
101
Thin-walled members with non-symmetrical cross-sections are vital to engineering structures, offering material efficiency and structural integrity. However, unsymmetrical loading on these members leads to complex stress distributions, resulting in simultaneous bending and twisting can cause deformation or structural failure. The interaction between bending and twisting requires detailed analysis to ensure structural resilience.
The concept of the shear center is crucial in countering the...
The concept of the shear center is crucial in countering the...
101
Eccentric Axial Loading in a Plane of Symmetry
165
Eccentric axial loading occurs when an axial load is applied away from the centroidal axis of a structural member. This scenario is common in engineering, where structural elements may not be directly aligned due to various design or functional requirements.
165
Masonry Curtain Walls
1.0K
Masonry curtain walls employ brick or stone veneers supported by the building's structure to form an external cladding system that is both aesthetically appealing and functional. These walls are erected through two principal techniques, first by traditional layering of masonry units and second by using prefabricated panels. Traditional construction relies on steel shelf angles attached to the spandrel beam for support, with high-bond mortars ensuring secure attachment of masonry veneer...
1.0K