在子血管图中测量动脉直径,用于神经血管疾病建模应用和设备测试
Yasmine Khan1, Jack Franklin1, Jonathan Cortese1,2
1Department of Radiology, Mayo Clinic, Rochester, MN, USA.
概括
这项研究为在神经血管研究中使用的新西兰白模型提供了必要的血管测量. 这些数据简化了选择合适的子血管系统,用于未来的体内设备测试和动脉瘤研究.
科学领域:
- 临床前研究 临床前研究
- 神经血管研究 神经血管研究
- 动物模型动物模型
背景情况:
- 新西兰白是神经血管研究的宝贵临床前模型.
- 在子动脉中诱导动脉瘤允许体内装置测试.
- 档案的血管图为子模型中的血管测量提供了一个资源.
研究的目的:
- 测量和记录新西兰白的关键动脉直径.
- 为未来的神经血管研究和设备测试提供血管数据.
- 描述血管解剖学和识别子模型中的变异.
主要方法:
- 对2005-2024年档案的子血管图分析.
- 使用ImageJ软件进行精确的动脉直径测量.
- 解剖血管变化的分类.
主要成果:
- 在170只雌性子的39个兴趣点记录了血管测量.
- 1型大动脉形解剖学被确定为最常见的 (85%).
- 为动脉瘤模型和对照提供了动脉大小的数据.
结论:
- 现有的血管测量简化了未来的神经血管研究,通过允许基于大小的子模型的选择.
- 提供了对弹性酶诱导动脉瘤和周围血管系统的见解.
- 便于对子关键动脉的大小进行比较.
相关概念视频
Blood Flow
Blood is pumped by the heart into the aorta, the largest artery in the body, and then into increasingly smaller arteries, arterioles, and capillaries. The velocity of blood flow decreases with increased cross-sectional blood vessel area. As blood returns to the heart through venules and veins, its velocity increases. The movement of blood is encouraged by smooth muscle in the vessel walls, the movement of skeletal muscle surrounding the vessels, and one-way valves that prevent backflow.
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Arteries and Arterioles
Arteries, the vasculature responsible for transporting blood from the heart, possess robust walls capable of enduring the elevated pressures exerted by the heartbeat. Arteries near the heart are especially thick-walled and enriched with elastic fibers across their three tunics, classifying them as elastic or conducting arteries. These arteries, usually with a diameter exceeding 10 mm, are characterized by their ability to dilate in response to the blood pumped from the heart's ventricles and...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...