1岁以下婴儿的血压参考值. 振荡计和选择参数的参数
Enrique Blanca-Jover1,2, Andrea Villanueva-Garcia1,2, Francisco Contreras-Chova1,3
1Department of Paediatrics, School of Medicine, University of Granada, Granada, Spain.
Acta paediatrica (Oslo, Norway : 1992)
|June 12, 2025
概括
这项研究提供了新的婴儿血压参考值,使用了振荡计和听力学方法. 这些发现为临床实践中评估儿科血压提供了最新的指导.
科学领域:
- 儿科 儿科 儿科
- 心血管健康 心血管健康
- 医学测量 医学测量
背景情况:
- 婴儿血压评估研究不足,缺乏当前的参考标准.
- 现有的振荡度参考图已经有30多年的历史了.
- 对于婴儿,没有可用的辅助血压参考值.
研究的目的:
- 为婴儿建立新的振荡度和听觉血压参考值.
- 为了在婴儿中比较振荡度和听力学方法之间的血压测量.
- 为儿科血压监测提供最新的,临床上适用的数据.
主要方法:
- 招募了228名14天至364天的健康婴儿.
- 获得了每个婴儿的听力和振荡计血压读数.
- 分析数据,将婴儿分为四个季度年龄组.
主要成果:
- 在振荡计和听力计血压读数之间观察到显著的差异.
- 根据年龄,性别或轻微的健康状况,没有发现血压测量的显著差异.
- 为两种测量方法建立了新的参考值.
结论:
- 婴儿血压的新振荡度和听力参考值现在可用于临床使用.
- 建议进行辅助测量以确认婴儿的血压值.
- 该研究为例行儿科血压监测提供了必要的数据.
相关概念视频
Special considerations while measuring blood pressure
709
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
709
Sites for measruring blood pressure
1.5K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.5K
Measurement of Blood Pressure
892
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
892
Assessment of blood pressure in brachial artery(two-step method)
660
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
660
Assessment of blood pressure in brachial artery(one-step method)
560
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
560
Equipments Used To Measure Blood Pressure
839
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
839