相关实验视频
Updated: Jun 15, 2025

11:34
Scattering And Absorption of Light in Planetary Regoliths
Published on: July 1, 2019
10.3K
概括
研究人员使用光学增益实现了零前向光的超散射,从而实现了第二个Kerker效应,用于增强子波长散射器的方向控制.
科学领域:
- 光子学和元材料研究
- 纳米光子学 纳米光子学
- 电磁学 电磁学 电磁学 电磁学
背景情况:
- 超散射显著增强了超出单通道限制的子波长物体的光散射.
- 现有的超散射方法通常会导致非零的前向散射光.
- 应用包括光学传感,天线和先进的成像.
研究的目的:
- 为了研究实现零前向散射光的超散射的可能性.
- 探索光学增益在控制散射现象中的作用.
- 介绍和定义一种新现象,称为"Kerker超散射".
主要方法:
- 在次波长散射器中对光物质相互作用的理论研究.
- 利用光学增益来操纵散射特性.
- 分析超散射和第二个Kerker效应之间的相互作用.
主要成果:
- 证明光学增益可以使零前向散射光的超散射.
- 展示了单通道超散射和第二个Kerker效应的同时实现.
- 在这种情况下,确定了第二个Kerker效应作为零向前散射的机制.
结论:
- 拟议的方法称为Kerker超散射,它提供了一种控制光散射方向性的新方法.
- 这一现象对开发高度定向的光学设备有着重大影响.
- 光学增益是实现奇特的散射效应 (如零向前散射) 的关键因素.
相关概念视频
Scanning Electron Microscopy
4.2K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.2K
Super-resolution Fluorescence Microscopy
6.9K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
6.9K
Atomic Emission Spectroscopy: Interference
175
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
175
Colloidal precipitates
528
The high insolubility of some precipitates can result in an unfavorable relative supersaturation. This can lead to colloidal particles with a large surface-to-mass ratio, where adsorption is promoted. For instance, in the precipitation of silver chloride, silver ions are adsorbed on the surface of the colloidal particles, forming a primary layer. This layer attracts ions of opposite charge (such as nitrate ions), forming a diffuse secondary layer of adsorbed ions. This electric double layer...
528
Mass Analyzers: Overview
620
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
620

