喷嘴流量计具有不同的接结构的热应力和热变形
Hai-Bing Jiang1, Ze-Zhou Yang2, Yu-Liang Zhang1
1College of Mechanical Engineering, Quzhou University, Quzhou, China.
PloS one
|June 16, 2025
概括
这项研究研究了接结构如何影响喷嘴流量计的热应力和变形. 增加接金属的形角度可以减少应力和变形,优化高温测量.
科学领域:
- 机械工程 机械工程
- 材料科学 材料科学 材料科学
- 流体动力学 流体动力学
背景情况:
- 喷嘴流量计对于高温介质测量至关重要.
- 了解接结构的影响对于性能和安全至关重要.
研究的目的:
- 为了研究接结构对喷嘴流量计热应力和变形的影响.
- 在高温下分析热特性的数值模拟.
主要方法:
- 设计了10个不同的接结构,不同的几何参数.
- 对高温喷嘴流量计模型进行数值计算的热应力和变形.
主要成果:
- 增加接金属的形角度导致进出口处的热应力降低.
- 热变形表现出最小的变化,随着形角度的增加.
- 接金属的距离,宽度和角开口对整体热应力和变形产生了很小的影响.
结论:
- 接金属的形角度是控制热应力和变形的关键因素.
- 优化接几何学可以提高喷嘴流量计在高温应用中的可靠性.
相关概念视频
Temperature Dependent Deformation
201
In a nonhomogeneous rod made up of steel and brass, restrained at both ends and subjected to a temperature change, several steps are involved in calculating the stress and compressive load. Due to the problem's static indeterminacy, one end support is disconnected, allowing the rod to experience the temperature change freely. Next, an unknown force is applied at the free end, triggering deformations in the rod's steel and brass portions. These deformations are then calculated and added...
201
Pipe Flowrate Measurement
830
In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
The orifice meter is a simple,...
830
Residual Stresses
286
Residual stresses reside in a structure even after removing the original stress inducer. This phenomenon often arises from varied plastic deformations across different parts of a structure. Consider a rod stretched beyond its yield point. It will not regain its original length due to permanent deformation. Even after load removal, the rod does not entirely lose stress because of uneven plastic deformations, resulting in residual stresses. The computation of these stresses in structures is...
286
Thermal Strain
2.5K
Thermal strain is a concept that arises when we consider how temperature changes affect structures. Unlike the conventional assumption that structures remain constant under load, real-world scenarios often involve temperature fluctuations that can significantly impact these structures. Consider a homogeneous rod with a uniform cross-section resting freely on a flat horizontal surface. If the rod's temperature increases, the rod elongates. This elongation is proportional to the temperature...
2.5K
Thermal Stress
2.6K
If the temperature of an object is changed while it is prevented from expanding or contracting, the object is subjected to stress. The stress is compressive if the object expands in the absence of constraint and tensile if it contracts. This stress resulting from temperature change is known as thermal stress. It can be quite large and can cause damage. To avoid this stress, engineers may design components so they can expand and contract freely. For instance, on highways, gaps are deliberately...
2.6K
Thermal expansion and Thermal stress: Problem Solving
1.4K
San Francisco's Golden Gate Bridge is exposed to temperatures ranging from -15 °C to 40 °C. At its coldest, the main span of the bridge is 1275 m long. Assuming that the bridge is made entirely of steel, what is the change in its length between these temperatures?
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
1.4K