非线性家庭负载的数据集,用于有效功率过器的验证
Vrindarani Nuñez-Ramírez1, Néstor F Guerrero-Rodríguez1, Rafael Omar Batista-Jorge1
1Engineering Sciences, Pontificia Universidad Católica Madre y Maestra PUCMM, Av. Abraham Lincoln Esq. Romulo Betancourt, 2748, Santo Domingo, Dominican Republic.
Data in brief
|June 19, 2025
概括
本研究引入了多米尼加共和国非线性家庭电力负载的新数据集. 这些数据有助于分析电力质量,并为现代电气系统制定和缓解策略.
科学领域:
- 电气工程 电气工程
- 电力系统分析 分析 分析
- 数据科学数据科学数据科学
背景情况:
- 非线性家庭负载通过引入波扭曲,显著影响功率质量.
- 了解这些负载特性对于有效的电力系统管理和稳定性至关重要.
- 现有的数据集可能无法充分反映当代住宅能源消耗的多样性.
研究的目的:
- 来自多米尼加共和国圣多明戈的非线性家庭负载的综合数据集.
- 提供高分辨率的电波形数据,用于电源质量研究和律分析.
- 为了促进功率电子设备和模拟模型的验证.
主要方法:
- 结构化数据收集和处理方法.
- 使用METREL MI 2883功率质量分析仪进行测量.
- 记录了七种不同的家用设备的高分辨率电压和电流波形.
主要成果:
- 收集了详细的电气参数,包括形状,电压,电流,频率和峰值因子.
- 从代表性的非线性负载 (如冰箱,空调和充电器) 获取的数据.
- 建立了一个公开可用的数据集,供公众研究使用.
结论:
- 该数据集使得先进的电力质量分析和开发和缓解技术成为可能.
- 它适用于验证主动功率过器和控制器硬件在循环 (CHIL) 模拟.
- 这些数据支持电力系统研究,过器设计和能源效率方面的研究.
更多相关视频
相关概念视频
Maximum Power Flow and Line Loadability
186
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
186
The Power Flow Problem and Solution
348
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the...
348
Load-frequency control
268
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
268
Energy and Power Signals
634
In an electrical system with a resistor, voltage and current signals facilitate the measurement of power and energy across the resistor. For a continuous-time signal, the total energy over a time interval is defined as the integral of the square of the signal's magnitude over that interval. Mathematically, this is expressed as:
634
Distributed Loads
629
Distributed loads are a common type of load that engineers and scientists encounter in various practical situations. Distributed loads often refer to a type of load spread over a surface or a structure and can be modeled as continuous force per unit area.
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
629
Power Factor Correction
275
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
275