使用传输线路阻抗方法的方向保护方案
Ahmed R Adly1, Mahmoud A Elsadd2, Mahmoud M Elgamasy3
1Nuclear Search Center, Egyptian Atomic Energy Authority, Cairo, Egypt. ahemd_adly@yahoo.com.
Scientific reports
|June 20, 2025
概括
本研究提出了一种新的故障方向识别技术,用于使用正阻抗方法保护输电线路. 该方法准确地确定故障方向,即使在高电阻和CT和等具有挑战性的条件下.
科学领域:
- 电气工程 电气工程
- 电力系统保护保护 电力系统保护
背景情况:
- 准确的故障方向识别对于输电线路保护方案至关重要.
- 现有的方法面临着高阻力,噪声和系统变化的挑战.
研究的目的:
- 为输电线路开发和验证一种新的定向保护技术.
- 在各种故障场景下评估拟议方案的性能.
主要方法:
- 使用瞬间正序电压和电流组件.
- 计算阻抗矩阵 (Z矩阵) 来确定故障方向.
- 使用ATP-EMTP软件进行模拟和验证.
主要成果:
- 建议的正阻抗方法成功地确定了故障方向.
- 该方案证明了对高抗故障,远端故障和跨国故障的稳定性.
- 尽管有功率流变化,单杆动,CT和和噪音,性能仍然可靠.
结论:
- 提出的定向保护技术是可行的和准确的.
- 该方法为输电线路保护提供了可靠的解决方案,在各种具有挑战性的条件下优于现有的方案.
更多相关视频
09:36Continuous-Wave Propagation Channel-Sounding Measurement System - Testing, Verification, and Measurements
Published on: June 25, 2021
3.2K
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
8.6K
相关概念视频
Line Protection with Impedance Relays
138
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
138
Zones of Protection
354
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
354
Lossless Lines
180
In electrical engineering, a lossless transmission line is characterized by a purely imaginary propagation constant and a resistive characteristic impedance. The ABCD parameters, which describe the relationship between the input and output voltages and currents, indicate an equivalent π circuit with an imaginary series impedance and a shunt admittance. This results in a transmission line that, when the product of the phase constant (beta) and the length of the line is less than pi,...
180
Series Impedances: Three-Phase Line
155
Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
155
Directional Relays
205
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
205
Transmission Line Design Considerations
221
Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
221