Jeevika1, Sagar Kulkarni1, Faisal Jamal1
1Department of Radiology, University of Pennsylvania & Perelman School of Medicine, 3400 Spruce Street, Philadelphia, PA 19102, USA.
European journal of radiology
|June 24, 2025
概括
平衡稳态自由前行 (bSSFP) 是一个关键的磁共振成像 (MRI) 技术. 它提供高对比度,明亮的流体图像,对于诊断各种疾病至关重要.
科学领域:
- 医学成像物理 医学成像物理
- 生物医学工程 生物医学工程
- 放射学 放射学是一门学科.
背景情况:
- 磁共振成像 (MRI) 是从核磁共振 (NMR) 光谱学演变而来的.
- 均衡稳定状态自由前行 (bSSFP) 是一个重要的MRI技术.
- bSSFP的根源在于早期的NMR物理学,并在20世纪80年代和90年代末显著发展.
研究的目的:
- 审查bSSFP的历史发展.
- 详细介绍bSSFP的技术成熟和临床采用.
- 为突出bSSFP在推进诊断成像技术中的作用.
主要方法:
- 对NMR和MRI发展的历史审查.
- 对bSSFP技术里程碑和创新的分析.
- 检查临床应用和正在进行的研究.
主要成果:
- bSSFP提供高信号噪声比和明亮流体对比.
- 关键的进步包括脂肪抑制,磁化准备和人工物减少.
- bSSFP对于心脏,血管和腹部成像至关重要.
结论:
- bSSFP已经成为快速,高对比度MRI的支柱.
- 持续的改进提高了其在功能,定量和扩散成像中的实用性.
- bSSFP体现了诊断成像技术进步的跨学科性质.
相关概念视频
Magnetic Resonance Imaging
7.3K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
7.3K
Atomic Nuclei: Nuclear Relaxation Processes
728
In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis, the precessing magnetic moments are randomly oriented around the z-axis.
728
Atomic Nuclei: Larmor Precession Frequency
1.7K
The earth's gravitational field produces a 'twisting force' perpendicular to the angular momentum of a spinning mass (such as a spinning top) that causes the mass to 'wobble' around the gravitational field axis in a phenomenon called precession. Similarly, the magnetic moment (μ) of a spinning nucleus precesses due to an external magnetic field directed along the z-axis. The precession of the magnetic moment vector about the magnetic field is called Larmor precession,...
1.7K
Atomic Nuclei: Magnetic Resonance
766
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
766
Imaging Studies IV: Magnetic Resonance Imaging
60
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
60
NMR Spectrometers: Resolution and Error Correction
784
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
784