微线与微带磁弹性传感器用于基于振动的结构健康监测矩形混凝土梁
Christos I Tapeinos1, Dimitris Kouzoudis1, Kostantis Varvatsoulis1
1Department of Chemical Engineering, University of Patras, 26504 Patras, Greece.
Sensors (Basel, Switzerland)
|June 27, 2025
概括
磁弹性传感器,带和微线形状,有效监测混凝土梁的结构健康. 两种传感器类型都检测到裂,带式传感器显示更强的信号,尽管频率变化对于损坏评估来说是相似的.
科学领域:
- 材料科学 材料科学 材料科学
- 结构工程 结构工程
- 传感器技术 传感器技术
背景情况:
- 结构健康监测 (SHM) 对基础设施安全至关重要.
- 磁弹性传感器提供了一个有前途的非破坏性评估方法.
- 梅特格拉斯材料具有独特的磁性,适用于传感应用.
研究的目的:
- 为了比较带和微线磁弹性Metglas传感器用于混凝土梁SHM.
- 评估传感器在检测和量化结构损坏方面的性能.
- 为了研究热对传感器信号增强的影响.
主要方法:
- 在混凝土梁上固定带和微线Metglas传感器.
- 诱导裂并使梁承受曲振动.
- 无线记录磁信号使用线圈和快速里埃分析.
- 分析信号光谱的曲模式频率和损坏引起的变化.
- 研究热对传感器性能的影响.
主要成果:
- 带和微线传感器都成功检测到结构损伤.
- 带式传感器提供了比微线传感器强1.4倍的信号.
- 与损坏相关的相对频率转移是最小的 (<1%) 和两种传感器类型的相似.
- 热将传感器信号增强了10-30%,特别是在带式传感器.
结论:
- 带式磁弹性传感器和微线磁弹性传感器都适用于混凝土结构健康监测.
- 带和微电线之间的选择可能取决于所需的信号强度.
- 热是一种有效的方法来提高传感器的灵敏度.
相关概念视频
Distribution of Stresses in a Narrow Rectangular Beam
245
In studying beam stress distribution, examining an elemental section is essential. To determine the average shearing stress on this face, the calculated shear is divided by the surface area. Importantly, shearing stresses on the beam's transverse and horizontal planes mirror each other, indicating a consistent stress distribution along the upper region of the beam. Notably, shearing stresses are absent at the beam's upper and lower surfaces due to the absence of applied forces in these...
245
Beams with Unsymmetric Loadings
168
Analyzing a supported beam under unsymmetrical loadings is essential in structural engineering to understand how beams respond to varied force distributions. This analysis involves calculating the deflection and identifying points where the slope of the beam is zero, which are crucial for ensuring structural stability and functionality.
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
168
Design Example: Strain Gauge Bridge or Wheatstone Bridge
548
The utilization of strain gauges as transducers for converting mechanical strain into electrical signals is a common practice in various engineering applications. These strain gauges are frequently integrated into Wheatstone bridge circuits to accurately measure parameters such as force or pressure. Within this context, each element within the circuit exhibits a resistance that undergoes subtle variations when subjected to mechanical strain. The primary objective is to convert minuscule...
548
Microcracking in Concrete
212
Microcracking in concrete refers to the tiny cracks that can form within the material even before any external load is applied. These microcracks typically occur at the interface between the coarse aggregate and the hydrated cement paste, often as a result of differential volume changes prompted by variations in stress-strain behavior, as well as thermal and moisture movement. Initially, these microcracks remain stable and do not grow substantially until the concrete is stressed to about 30...
212
Beams with Symmetric Loadings
246
The moment-area method is an analytical tool used in structural engineering to determine the slope and deflection of beams under various loads. Consider a cantilever with a concentrated load and moment at the free end. The first step is constructing a free-body diagram to calculate the reactions at the fixed end. Next, the bending moment diagram is plotted to visualize how the bending moment varies along the beam's length, focusing on points where the bending moment equals zero.
The M/EI...
The M/EI...
246
Dynamic Modulus of Elasticity of Concrete
556
The dynamic modulus of elasticity assesses how a concrete structure deforms under impact or dynamic loads. It is typically higher than the static modulus of elasticity, measured under slow, steady loading conditions.
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
556