使用网络DEA和GA模型评估土耳其电力分配中的能源效率
1Ondokuz Mayıs University, Samsun, Türkiye. serpil.gumustekin@omu.edu.tr.
Scientific reports
|July 2, 2025
概括
这项研究使用网络数据包裹分析 (NDEA) 和遗传算法 (GA) 评估了土耳其的配电公司. 萨卡利亚EDC表现出色,在整个发电,传输和分销过程中表现出最佳性能.
科学领域:
- 能源经济学 能源经济学
- 运营研究 运营研究
- 环境可持续性 环境可持续性
背景情况:
- 评估电力分配中的能效对于可持续发展至关重要.
- 传统的方法可能无法完全捕捉到发电流程的复杂性.
- 土耳其的能源部门需要高效的运营战略.
研究的目的:
- 评估土耳其发电公司的能源效率.
- 将传统的数据包围分析 (DEA) 与网络 DEA (NDEA) 和遗传算法 (GA) 进行比较.
- 确定该行业的最佳实践和改进领域.
主要方法:
- 员工数据包装分析 (DEA) 用于初始效率评估.
- 使用网络DEA (NDEA) 来分析子过程:生成,传输和分配.
- 应用遗传算法 (GA) 用于优化输入输出配置和评估可再生能源效率.
主要成果:
- 与传统的DEA相比,网络DEA提供了更现实的效率得分.
- 萨卡利亚EDC被确定为一个基准,在所有三个子过程中实现了效率.
- 基因算法产生的效率比传统的DEA方法高约10%.
- 在2015年评估的公司中,只有Boğaziçi EDC被认为是高效的.
结论:
- 通过剖析运营阶段,NDEA提供了一种全面的能源效率方法.
- 通过提供优化见解,GA增强了效率分析.
- 调查结果强调需要有针对性的投资来提高土耳其的能源分配效率和可持续性.
相关概念视频
Distribution Reliability and Automation
167
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
167
Secondary Distribution
140
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
140
Maximum Power Flow and Line Loadability
185
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
185
Power System Distribution
320
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
320
Energy Losses in Transformers
985
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
985
The Power Flow Problem and Solution
348
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the...
348