基于弹性振荡器的网络攻击检测,用于对逆变器接口的岛屿微电网进行分布式二次控制
Fahimeh Zargarzadeh-Esfahani1, Bahador Fani2, Babak Keyvani-Boroujeni3
1Department of Electrical Engineering, Isf.C., Islamic Azad University, Isfahan, Iran.
Scientific reports
|July 2, 2025
概括
本研究介绍了岛屿交流微电网的网络弹性战略,增强对虚假数据注入 (FDI) 和拒绝服务 (DoS) 攻击等网络威胁的二次控制,以确保稳定性.
科学领域:
- 电气工程 电气工程
- 计算机科学 计算机科学
- 网络安全 网络安全
背景情况:
- 微电网越来越容易受到针对二级控制机制的网络攻击.
- 假数据注入 (FDI) 和拒绝服务 (DoS) 攻击破坏了微电网的稳定性和性能.
- 现有的控制策略在网络威胁下难以保持稳定.
研究的目的:
- 为岛屿交流微电网提出一个强大的网络弹性战略.
- 加强频率监管和权力共享的抗击网络攻击的弹性.
- 通过各种微电网拓来验证拟议的方法.
主要方法:
- 适应性异常检测和层次控制机制的整合.
- 在各种网络攻击场景下使用MATLAB/Simulink进行模拟分析.
- 对通信链路的外国直接投资和DoS攻击的有效性评估.
主要成果:
- 传统的控制在网络攻击期间无法保持稳定,导致偏差.
- 提出的方法成功地检测和减轻网络攻击.
- 系统稳定性和稳健运行得到恢复,确保可靠的电力分配.
结论:
- 拟议的网络弹性战略有效地减轻了岛屿交流微电网中的网络攻击.
- 这种方法确保了频率稳定和平衡的电力共享.
- 在网络化,循环式和总线式微电网配置中验证了适应性.
更多相关视频
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.8K
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
2.1K
相关概念视频
Power System Three-Phase Short Circuits
150
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
150
Reclosers and Fuses
166
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
166
Line Protection with Impedance Relays
138
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
138
Secondary Distribution
140
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
140
Power System Distribution
320
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
320
Radial System Protection
153
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
153