基于INFO-RF的故障诊断和分析方法用于巴斯巴.
Chen Xue1, Jian Zhu2, Haiou Cao3
1State Grid Jiangsu Electric Power Co., Ltd., Yangzhou Power Supply Company, Yangzhou, 225009, China. xchen232@tutamail.com.
Scientific reports
|July 2, 2025
概括
本研究介绍了一种INFO-RF模型,用于精确的总线轴故障诊断和电力系统中电阻预测. 该方法通过提高故障识别准确度,显著提高了电网安全性和稳定性.
科学领域:
- 电气工程 电气工程
- 电力系统分析 分析 分析
- 网格中的人工智能
背景情况:
- 电力系统的规模和智能正在迅速扩大.
- 准确和及时的总线杆故障诊断对于电网稳定性至关重要.
- 对于复杂的电力系统,现有的方法需要改进.
研究的目的:
- 开发一个先进的方法,用于总线条故障诊断和阻力预测.
- 提高智能电网故障分析的准确性和效率.
- 通过精确的故障识别,提高电力系统运行的可靠性.
主要方法:
- 建立了一个双杆动力系统模拟模型.
- 使用根均方 (RMS) 提取了关键的电量 (差电流,总线连接电流,电压).
- 矢量的加权平均值 (INFO) 算法优化了随机森林 (RF) 超参数,以改善预测.
主要成果:
- 在测试组中,INFO-RF模型获得了98.472%的准确性.
- 该模型准确地识别了总线条故障类型,并预测了故障阻力.
- 性能明显超过了BP神经网络,GRNN和决策树等传统方法.
结论:
- INFO-RF模型为总线条故障诊断提供了一个高度准确和有效的解决方案.
- 这种方法为电力系统的故障定位和维护提供了至关重要的支持.
- 该方法有助于确保日益复杂的电网的安全和稳定运行.
更多相关视频
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
5.9K
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
2.1K
相关概念视频
Bus Impedance Matrix
182
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
182
Fault Types
130
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
130
Power System Three-Phase Short Circuits
150
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
150
Differential Relays
268
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
268
Three-Phase Short Circuit—Unloaded Synchronous Machine
239
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
239
Series R—L Circuit Transients
156
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
156