在现有住宅建筑中对被动超低能耗建筑外性能进行参数分析
Hui Fang1, Wen-Ke Li2, Peng Dai2
1Civil Engineering and Architecture, Shandong University of Science and Technology, Qingdao, 266590, China. fanghui203@163.com.
Scientific reports
|July 2, 2025
概括
改造现有住宅建筑以被动超低能耗战略显著提高了节能. 这种方法可以节省大量的能源,支持绿色发展和减少碳排放的目标.
科学领域:
- 建筑科学与能源效率建设
- 可持续的建筑 可持续的建筑
- 环境工程 环境工程
背景情况:
- 住宅建筑是主要的能源消费者,经常表现出高消耗,低舒适度和过时的基础设施.
- 推动绿色和低碳的生活方式需要改善建筑的能源性能,重点是节能和减少碳排放.
研究的目的:
- 分析现有住宅建筑包裹和内部墙壁的热性能.
- 为了比较原始,改装和被动超低能阶段的隔热性能.
- 为了节能,对被动超低能建筑外组件进行参数分析.
主要方法:
- 在山东省青岛的一住宅楼的案例研究.
- 现场调查和DesignBuilder软件模拟用于性能分析.
- 对被动超低能耗建筑外组件进行参数分析.
主要成果:
- 与原始建筑相比,建筑外的被动超低能耗改造可以节省高达87.06%的能源.
- 与初步改造阶段相比,节能达到84.9%.
- 在隔热性能方面取得显著的改进.
结论:
- 被动超低能耗改造对于提高现有住宅建筑节能效果非常有效.
- 该研究为在现有住房库中实施节能和减少碳排放的战略提供了理论基础.
- 参数分析为优化超低能耗建筑物的外性能提供了宝贵的见解.
相关概念视频
Thermal Insulation in Masonry Walls
196
In hot, dry climates, the thermal mass of masonry walls can be beneficial, absorbing heat during the day and releasing it at night, thereby stabilizing indoor temperatures. However, in most other climates, additional insulation is necessary to enhance thermal resistance.
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
196
Design Example: Sustainability in Concrete Building
229
As the construction industry moves towards more eco-friendly practices, concrete's adaptability and its ability to incorporate sustainable features make it a key material in the drive towards greener building solutions.
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
229
Conduction, Convection and Radiation: Problem Solving
1.4K
There are three methods by which heat transfer can take place: conduction, convection, and radiation. Each method has unique and interesting characteristics, but all three have two things in common: they transfer heat solely because of a temperature difference; and the greater the temperature difference, the faster the heat transfer.
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
1.4K
Insulation Coordination
233
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
233
Energy Conservation and Bernoulli's Equation
9.4K
Applying the conservation of energy principle or the work-energy theorem to an incompressible, inviscid fluid in laminar, steady, irrotational flow leads to Bernoulli's equation. It states that the sum of the fluid pressure, potential, and kinetic energy per unit volume is constant along a streamline.
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...
9.4K
Masonry Cavity Walls
1.1K
Cavity walls feature a hollow space between the outer and inner wythes, connected only by corrosion-resistant metal ties. When water seeps through the outer wythe, it descends within this cavity, intercepted by flashing and eventually exiting through weep holes. To enhance moisture resistance, the inner wythe's cavity side often receives damp-proofing, doubling as an air barrier. The cavity can also house insulation to mitigate heat transfer.
Maintaining a clean cavity during construction...
Maintaining a clean cavity during construction...
1.1K