评估LEM对不同电网拓和未来消费者份额的技术经济效益
Markus Doepfert1, Soner Candas1, Hermann Kraus2
1Technical University of Munich, TUM School of Engineering and Design, Chair of Renewable and Sustainable Energy Systems, Lichtenbergstr. 4a, 85748 Garching, Germany.
iScience
|July 4, 2025
概括
地方能源市场有效地整合了可再生能源,降低了平均能源价格和运营峰值功率. 这种创新方法提高了未来能源系统的电网稳定性和经济效率.
科学领域:
- 能源系统工程 能源系统工程
- 整合可再生能源的整合
- 智能电网是一种智能电网.
背景情况:
- 过渡到去中心化和可再生能源挑战了传统的电网.
- 像太阳能电池板和电动汽车这样的分布式能源 (DER) 需要新的市场设计.
- 地方能源市场 (LEM) 为管理DER整合提供了一个潜在的解决方案.
研究的目的:
- 研究LEM与传统市场设计之间的技术经济影响.
- 评估LEM对平均能源价格和峰值电力需求的影响.
- 为了评估跨多种电网拓和DER透水平的LEM性能.
主要方法:
- 对各种网格配置进行了全面的模拟.
- 模拟分布式能源的不同透水平.
- 分析了400个不同的模拟场景,将LEM与传统市场进行比较.
主要成果:
- 低功率电机显示出显著的经济效率和电网稳定性的改善.
- 99%的模拟场景显示,在LEMs下,平均能源价格较低.
- 80%的场景显示,随着LEM实施,运行峰值功率降低.
结论:
- 地方能源市场是整合DER和提高电网性能的一个有希望的解决方案.
- 低功耗电机可以大幅降低能源成本和峰值需求.
- 成功广泛采用LEM取决于尽量减少基础设施,管理成本和复杂性.
相关概念视频
Reducing Line Loss
196
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
196
Maximum Power Flow and Line Loadability
184
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
184
Secondary Distribution
140
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
140
Energy Losses in Transformers
982
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
982
Trophic Efficiency
21.8K
Trophic level transfer efficiency (TLTE) is a measure of the total energy transfer from one trophic level to the next. Due to extensive energy loss as metabolic heat, an average of only 10% of the original energy obtained is passed on to the next level. This pattern of energy loss severely limits the possible number of trophic levels in a food chain.
21.8K
Transformers in Distribution System
165
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
165