在不确定性和干扰的情况下,针对三级四脚整流器直流微电网的增强电网电流和直流电压规则
Ali Chebabhi1, Mohamed Fouad Benkhoris2, Naamane Debdouche3
1Electrical Engineering Laboratory, University of M'sila, 28000, M'sila, Algeria.
Scientific reports
|July 4, 2025
概括
本研究引入了一种新的控制方法,使用分数级扩展状态观察员 (FOESO) 与主动干扰排斥控制 (ADRC) 进行三级中性点紧 (NPC) 四脚整流器 (3LNPC-4LR). 这种方法提高了DC微电网的稳定性和在各种干扰下的性能.
科学领域:
- 电气工程 电气工程
- 控制系统 控制系统
- 电力电子 电力电子 电力电子
背景情况:
- 三级中性点紧 (NPC) 四脚整流器 (3LNPC-4LR) 对直流微电网至关重要.
- 现有的控制方法在与干扰和系统不确定性作斗争.
研究的目的:
- 为3LNPC-4LR.提出一个增强的电网侧电流和直流总线电压调节方法.
- 为了提高在各种干扰和不确定性下强度和性能.
主要方法:
- 将一个分数级扩展状态观察员 (FOESO) 纳入一个主动干扰拒绝控制 (ADRC) 框架.
- 基于FOESO的ADRC应用于内部电流和外部电压控制环.
- 通过Hardware-in-the-loop (HIL) 实时模拟进行验证.
主要成果:
- 实现了恒定和快速的动态直流总线电压.
- 确保了极好的电网侧电流质量和单位功率因子.
- 在干扰,不确定性和负载变化下表现出强大的稳定状态行为.
结论:
- 基于FOESO的ADRC在传统方法上提供了显著的优势.
- 观察到增强的设计灵活性,改进的跟踪,优越的干扰排斥和更高的可靠性.
- 该方法对3LNPC-4LR在DC微电网中有效.
相关概念视频
Bridge rectifier
851
The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
851
Generator Voltage Control
248
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand,...
248
Full wave rectifier
1.8K
A full-wave rectifier is a device that converts alternating current (AC) to direct current (DC) and is more efficient than its half-wave counterpart. It typically includes a center-tapped transformer, two diodes, and a load resistor. The secondary winding of the transformer is divided to provide two equal voltages of opposite polarities, which is the pivotal element of full-wave rectification.
1.8K
Power System Three-Phase Short Circuits
150
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
150
Voltage Doubler Circuit
876
A voltage doubler circuit integrates two main components: a clamping section and a rectifier section. The clamping section consists of a capacitor (C1) and a diode (D1), whereas the rectifier section is equipped with another diode (D2) and capacitor (C2). This circuit produces an output voltage with twice the amplitude of the sinusoidal input voltage.
876
Generation of Three-Phase Voltage
474
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
474