一种改进的YOLOv7-Tiny方法用于医疗输液监测中的液体水平检测
Yonghu Chang1, Changwen Pu1, Shijie Li2
1School of Medical Information Engineering, Zunyi Medical University, Zunyi 563000, China.
Computers in biology and medicine
|July 5, 2025
概括
这项研究引入了一种增强的YOLOv7微型模型,用于准确,实时的医疗输液液体水平检测. 改进的系统减少了患者的风险和医疗保健提供者的工作量.
科学领域:
- 医疗技术 医疗技术 医学技术
- 计算机视觉 计算机视觉
- 人工智能的人工智能
背景情况:
- 静脉注射输液监测需要不断关注,增加了患者的焦虑和医疗保健工作人员的工作量.
- 现有的液体水平检测方法在复杂的医疗环境中缺乏准确性和适应性.
研究的目的:
- 开发一种改进的基于YOLOv7-tiny的方法,用于在医疗输液监测中准确和实时检测液体水平.
- 为了提高检测准确度和适应复杂条件的适应性,并优化边缘设备部署.
主要方法:
- 提出了一个改进的YOLOv7微型模型,包含了新型模块:ELAN-DS-ELAN,DCN-ELAN和P-ELAN.
- 在不同条件下对4296张注释注释的输液瓶图像进行了训练.
- 使用回忆,mAP和推断速度评估性能.
主要成果:
- 改进的YOLOv7-tiny方法实现了88.319%的回忆率和90.102%的mAP@[0.5:0.95].
- 与基线YOLOv7-tiny相比,表现出优越的性能,具有可比的计算复杂性.
- 在嵌入式设备上确认了强大的实时功能.
结论:
- 拟议的方法显著提高了智能输液监测系统的准确性和可用性.
- 允许可靠的实时液体水平检测,减少医疗保健提供者的工作量和患者的风险.
- 显示了在医疗监测中更广泛应用的潜力.
更多相关视频
相关概念视频
Two-Compartment Open Model: IV Infusion
337
A two-compartment model is a vital tool in pharmacokinetics, providing an essential understanding of drug behavior, especially for those administered via zero-order intravenous infusion. This model outlines two compartments: the central compartment, where elimination occurs, and the peripheral compartment.
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
337
One-Compartment Model: IV Infusion
291
Intravenous (IV) infusion is often utilized when continuous and controlled drug delivery is necessary, such as during surgery or in the treatment of chronic diseases. This method offers numerous advantages, including immediate drug action, precise control over dosage, and bypassing the first-pass metabolism.
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
291
Precipitation Titration: Endpoint Detection Methods
2.1K
In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
In the Volhard method, a standard excess of AgNO3 is first added to the...
2.1K
Rise of Liquid in a Capillary Tube
2.3K
When very thin cylindrical tubes, called capillaries, are dipped in a liquid, the liquid rises or falls in the tube compared to the surrounding liquid. This phenomenon is called capillary action. Capillary action occurs due to the combination of two opposing forces: the cohesive forces of the liquid, which cause it to stick to itself and form a rounded shape, and the adhesive forces between the liquid and the walls of the container, which cause the liquid to be attracted to the container walls.
2.3K
Measurement of Fluid Pressure
313
Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
313
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
146
Clearance is a key pharmacokinetic parameter that quantifies the volume of body fluid from which a drug is entirely removed within a specific time frame. It is crucial in assessing how a drug is eliminated from the body and has critical clinical applications.
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
146