使用基于注意GRU的故障分类器 (AGFC-Net) 在电力系统中检测故障
Deepen Khandelwal1, Prateek Anand1, Mayukh Ray1
1School of Electronics Engineering, Vellore Institute of Technology, Chennai, 600127, Tamil Nadu, India.
Scientific reports
|July 6, 2025
概括
这项研究引入了基于注意力GRU的故障分类器 (AGFC-Net),用于先进的故障检测. AGFC-Net的准确率达到99.52%,明显超过工业系统中的传统方法.
科学领域:
- 工程 工程师 工程师 工程师
- 计算机科学 计算机科学
- 人工智能的人工智能
背景情况:
- 故障检测对于系统可靠性和生产率至关重要.
- 传统的方法在准确性,特征提取和通用性方面扎.
- 未解决的故障会导致系统故障和昂贵的停机时间.
研究的目的:
- 开发一种先进的故障检测系统,克服传统方法的局限性.
- 增强特征提取和时间依赖性学习,以改进故障分类.
主要方法:
- 提出了一个基于注意力GRU的故障分类器 (AGFC-Net).
- 集成了一个复杂的注意力机制与门式循环单元 (GRU).
- 专注于关键的故障特征和时间相关性用于分类.
主要成果:
- AGFC-Net 实现了 99.52% 的高故障检测准确度.
- 与传统的机器学习和深度学习算法相比,表现出更高的性能.
- 即使在噪音条件下,也表现出有效的性能.
结论:
- AGFC-Net为自主故障诊断提供了一个强大,适应性和可扩展的解决方案.
- 该方法增强了智能和可靠的故障检测系统.
- 为提高电网和工业应用的可靠性铺平了道路.
相关概念视频
Power System Three-Phase Short Circuits
150
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
150
Fault Types
130
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
130
Reclosers and Fuses
166
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
166
Bus Impedance Matrix
182
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
182
Control of Power Flow
317
There are several methods to control power flow in power systems:
317
Zones of Protection
352
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
352