揭露隐藏的污染物:血液透析和腹腔透析液中的微塑料的系统量化和表征
Ekrem Kara1, Kamil Konur2, Yasemen Şentürk Koca3
1Faculty of Medicine, Department of Nephrology, Recep Tayyip Erdogan University, Rize, Türkiye. ekrem.kara@erdogan.edu.tr.
BMC nephrology
|July 7, 2025
概括
微塑料存在于透析液中,对接受血液透析和腹腔透析的患者构成潜在的健康风险. 需要进一步的研究来了解这种暴露的长期影响.
科学领域:
- 环境科学 环境科学
- 生物医学科学 生物医学科学
- 材料科学 材料科学 材料科学
背景情况:
- 微塑料 (MP) 由于其生物积累和毒性,越来越多地引起环境和健康的关注.
- 透析患者面临大量暴露于大量液体,这引发了人们对透析溶液中慢性MP暴露的担忧.
研究的目的:
- 系统地量化和描述血液透析 (HD) 和腹腔透析 (PD) 液体中的MP.
- 调查透析溶液中MPs相关的来源和潜在的健康风险.
主要方法:
- 分析30个透析溶液样本,使用富里埃变换红外光谱法 (FT-IR).
- 微塑料颗粒的量化和表征,包括聚合物识别.
主要成果:
- 在所有测试的溶液中检测到MP,主要是纤维 (聚乙烯,PVC,EVA被确定).
- 在HD和PD溶液之间,MP度没有显著差异 (p=0.86).
- 在HD溶液中发现的较大的MP粒子 (1.31毫米) 与PD溶液 (0.64毫米) 相比 (p=0.030).
- 据估计,PD患者的每周MP暴露率比HD患者高50% (p<0.001).
结论:
- 透析溶液是透析患者微塑性暴露的潜在来源.
- 进一步的研究对于了解慢性MP吸收对功能系统影响至关重要.
- 建议包括改善过,无聚合物材料,以及对医疗解决方案进行更严格的质量控制.
相关概念视频
Hemodialysis II: Procedure and Complications
143
DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
143
Hemodialysis I: Introduction
310
Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
310
Peritoneal Dialysis I: Introduction and Procedure
222
Peritoneal dialysis (PD) is a procedure that facilitates the exchange of solutes, waste products, electrolytes, and excess fluid between the blood in the peritoneal capillaries and a dialysis solution introduced into the peritoneal cavity.Principles of Peritoneal Dialysis (PD)Diffusion: Waste products such as urea and electrolytes move from high concentrations in the blood to low concentrations in the dialysate across the peritoneal membrane. This mechanism is driven by the concentration...
222
Dialysis
821
Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
821
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
111
Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...
111
Peritoneal Dialysis III: Nursing Management
157
Peritoneal dialysis, or PD, utilizes the peritoneal membrane as a filter to eliminate excess fluid and waste products. Effective nursing management is essential for ensuring patient safety, preventing complications, and promoting optimal function of the peritoneal dialysis process.Assessment and MonitoringNurses must thoroughly assess the patient before, during, and after each dialysis session. Regular monitoring includes vital signs, daily weight, fluid intake and output, and laboratory values...
157