关于超声波采集系统中编码激发的稳定性
Connor Challinor1, Frederic Cegla1
1Department of Mechanical Engineering, Imperial College London, Exhibition Road, South Kensington, London, SW7 2AZ, UK.
Ultrasonics
|July 8, 2025
概括
编码激发提高了超声波信号质量,但由于强度问题而面临有限的工业用途. 本研究确定符号不对称和错位是关键的降解因素,为可靠的应用提供了要求.
科学领域:
- 超声波测试 超声波测试 超声波测试
- 信号处理 信号处理
- 活动距离系统 活动距离系统
背景情况:
- 编码激发增强了超声波活动范围的信号质量.
- 编码激发的工业采用是有限的,可能是由于感知到的强度问题.
- 了解性能降低机制对于实际实施至关重要.
研究的目的:
- 研究在编码激发中导致性能降低的机制.
- 量化符号不对称和符号错位对信号质量的影响.
- 定义可靠的编码激发使用的硬件和操作要求.
主要方法:
- 对信号退化进行模拟和实验分析.
- 识别和描述符号不对称和错位的情况.
- 在各种硬件缺陷和非静止条件下对降解的评估.
主要成果:
- 由硬件缺陷引起的符号不对称性,以及符号错位,在非静止场景中,通过引入文物和减少振幅来降低信号质量.
- 量化了与特定不完美类型和错位相关的退化严重程度.
- 确定了操作条件,以保持信号退化低于40dB的值.
结论:
- 符号不对称和错位是限制编码激发强度的关键因素.
- 建立最低硬件要求和特定的检查条件可以确保高质量的结果.
- 这项研究为编码激发的可靠工业应用提供了一个框架.
更多相关视频
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
668
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
10.6K
相关概念视频
Ultrasonography
6.3K
Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
During an ultrasonography procedure, a handheld device called...
6.3K
Muscle Stimulation Frequency
2.7K
The contraction strength of muscles is regulated by motor neurons, which modulate the frequency of action potentials dispatched to the motor units based on the body's requirements. This process of varying the muscle stimulation frequency allows muscles to contract with a force that is precisely tailored to the needs of the moment, whether lifting a feather or a heavy box.
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
2.7K
Imaging Studies II: Ultrasonography
60
IntroductionUltrasonography, or renal ultrasound, is a noninvasive medical imaging technique that uses high-frequency sound waves to visualize the kidneys, ureters, bladder, and surrounding tissues.Indications for Urinary System UltrasonographyUrinary system ultrasonography is indicated in various clinical scenarios, such as:Kidney Stones (Urolithiasis): To detect and monitor the size and presence of kidney or urinary tract stones.Hydronephrosis: To assess the dilation of the renal pelvis and...
60
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
925
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
925