探索最佳心脏电子植入器件编程:减少不可操作的警报和评估临床结果
Mohamed A Mostafa1, George Bodziock1, Lindsey Cotten2
1Department of Cardiology, Wake Forest School of Medicine, Winston Salem, North Carolina, USA.
Journal of cardiovascular electrophysiology
|July 9, 2025
概括
优化心脏植入式电子设备 (CIED) 警报显著减少了不可执行的警报 (NAA) 和警报疲劳. 这种策略安全地提高了效率,而没有增加诸如中风或心脏突然死亡等不良事件.
科学领域:
- 心脏病学 心脏病学
- 生物医学工程 生物医学工程
- 医疗器械技术 医疗器械技术
背景情况:
- 心脏植入式电子设备 (CIED) 产生越来越多的远程数据.
- 过度的非可采取行动的警报 (NAA) 会导致临床医生的警报疲劳.
- 需要优化CIED警报参数.
研究的目的:
- 通过优化CIED警报参数来最大限度地减少NAA.
- 评估优化警报参数对临床结果的影响.
- 为了减少CIED患者的警觉疲劳.
主要方法:
- 包括536名拥有CIED的参与者.
- 413名患者的CIED被重新编程,以审查特定的心房动 (AF) 和非持续性心室动脉冲动 (NSVT) 警报.
- 在重编程前和后跟踪NAA;在随访期间评估缺血性中风和突然心脏死亡 (SCD).
主要成果:
- 重编程显著降低了NAA (p < 0.001).
- 在AF警报的重编程和对照组之间,缺血性中风的发生率相似.
- 与对照组相比,重新编程的患有NSVT警报的患者突然心脏病死亡的发生率较低.
结论:
- 基于指南的CIED警报参数优化显著降低了NAA负担.
- 这种方法并没有增加设备检测到AF或NSVT的患者的不良结果 (中风,SCD).
- 优化CIED警报可以安全地减少数据噪声并提高临床效率.
相关概念视频
Pulse rhythm
934
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
934
Cardiomyopathy V: Interprofessional Care
38
Managing cardiomyopathy involves addressing underlying or precipitating causes, treating heart failure with medications, and implementing dietary changes and a balanced exercise and rest regimen.Lifestyle ModificationsCardiomyopathy patients should adopt a low-sodium diet to reduce fluid retention and manage heart failure. A personalized exercise and rest plan helps maintain physical fitness without overstraining the heart. Avoiding alcohol and tobacco is essential to prevent further damage to...
38
Holter Monitor: 24-Hour Monitoring
298
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
298
Cardiopulmonary Resuscitation III: AED Use
73
Introduction to AEDAn Automated External Defibrillator (AED) is a portable medical device that analyzes the heart's rhythm and, if necessary, delivers an electrical shock to help the heart re-establish an effective rhythm during sudden cardiac arrest (SCA). SCA occurs when the heart suddenly and unexpectedly stops beating, leading to a loss of blood flow to the brain and other vital organs. In such emergencies, time is of the essence, and using an AED, combined with Cardiopulmonary...
73
Cardiomyopathy III: Hypertrophic Cardiomyopathy
61
Hypertrophic cardiomyopathy, or HCM, is an autosomal dominant genetic disorder characterized by asymmetric left ventricular hypertrophy without ventricular dilation. It is more common in men and is typically diagnosed in young, athletic adults.EtiologyHCM is primarily genetic and is caused by mutations in genes encoding sarcomeric proteins. Researchers have identified over 1400 mutations across at least 11 different genes. Among these, the most frequently occurring mutations are found in the...
61