在启蒙时代的医学中,脉的至高无上的地位
1Independent Researcher, Sydney, New South Wales, Australia.
Internal medicine journal
|July 10, 2025
概括
在18世纪的英国,医生将发烧视为一种独特的疾病,使用脉特征来诊断和指导病人治疗. 这种对脉的诊断重点后来被临床温度计所取代.
科学领域:
- 医学史 医学史 医学史
- 医学史 医学史 的历史
- 18世纪英国医疗保健
背景情况:
- 18世纪,志愿医院和护理院对少数英国穷人进行了治疗.
- 患有发烧和传染病的患者经常被排除在入院之外.
- 身体检查专注于脉冲特征进行诊断.
研究的目的:
- 探索脉冲检查在18世纪英国医学中的诊断意义.
- 了解脉冲特征如何为发烧性疾病的治疗决策提供信息.
- 追踪从脉冲诊断到临床温度计的历史转变.
主要方法:
- 对18世纪英国的历史医学实践和文学进行分析.
- 检查与发烧状况相关的诊断标准和治疗方法.
- 脉冲在医学诊断中的作用的历史背景.
主要成果:
- 在18世纪的英国医学思想中,发烧被认为是一种独特的疾病,而不仅仅是症状.
- 脉冲特征对于诊断发烧性疾病至关重要,特定的模式表明不同的情况 (例如,炎症发烧的快速边界脉冲, টাই型疾病的缓慢低幅度).
- 脉冲的诊断重要性随着19世纪中叶临床温度计的出现而逐渐减少.
结论:
- 脉冲在18世纪英国医学中是一个关键的诊断工具,用于理解和管理发烧性疾病.
- 医生使用脉冲变化来定制治疗,突出了复杂的诊断方法.
- 过渡到温度计标志着在客观测量疾病的重大进化.
相关概念视频
Pulse
1.1K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
1.1K
Regulation of Pulse
1.6K
Pulse regulation involves physiological mechanisms that ensure adequate blood flow throughout the body. The heartbeat, regulated by the autonomic nervous system, is influenced by hormonal balance, physical activity, and emotional state.
1.6K
Special considerations while measuring pulse
656
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
656
Equipments Used To Measure Blood Pressure
2.5K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.5K
Pulse amplitude and quality
2.2K
Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
2.2K
Measurement of Blood Pressure
1.5K
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1.5K