测量误差分布和优化研究 式超声波流量计在下游管道中的测量方法 干扰
Zhongzhi Yang1,2, Wei Wang1, Xianjie Liu1
1Chongqing Academy of Metrology and Quality Inspection, Chongqing 401123, China.
Sensors (Basel, Switzerland)
|July 12, 2025
概括
紧式超声波流量计由于流量干扰而面临准确性问题. 双通道测量方法显著提高了气体流量计的准确性,无论安装角度如何,将误差降至±2%.
科学领域:
- 机械工程 机械工程
- 流体动力学 流体动力学
- 测量科学 测量科学 测量科学
背景情况:
- 紧式超声波流量计对于现场气体流量测试至关重要.
- 流场干扰显著影响计量器的准确性,限制了应用.
研究的目的:
- 调查工业流量干扰对紧式超声波流量计准确度的影响.
- 评估方法,以提高在非理想流量领域的测量精度.
主要方法:
- 进行了实验和数值模拟,以分析干扰下游的流场.
- 评估了传统的反射和对角测量技术.
- 实施和评估了一种双通道测量方法.
主要成果:
- 传统方法对安装位置和角度有很高的依赖性,造成了很大的不确定性.
- 采用垂直传感器的双通道方法,有效控制 ±2%内的偏差.
- 这种双通道方法尽量减少了错误,无论安装角度如何,并减少了直管截面要求.
结论:
- 流量干扰对紧式超声波流量计的准确性构成重大挑战.
- 双通道测量方法为干扰流域中精确测量气流提供了可靠的解决方案.
- 这种增强的方法扩大了紧式超声波流量计在工业环境中的适用性.
相关概念视频
Pipe Flowrate Measurement
815
In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
The orifice meter is a simple,...
815
Pipe Flowrate Measurement: Problem Solving
602
A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is...
602
Measurement of Fluid Pressure
312
Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
312
Uncertainty in Measurement: Accuracy and Precision
81.6K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.
81.6K
Bernoulli's Equation: Problem Solving
1.5K
A Venturi meter is essential for measuring fluid flow rates in pipelines. It utilizes the relationship between fluid velocity and pressure described by Bernoulli's equation. When installed in a sewage system, the Venturi meter accurately determines the wastewater flow rate by measuring pressure differences.
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity...
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity...
1.5K
Uniform Depth Channel Flow
168
Uniform depth channel flow keeps fluid depth consistent along channels such as irrigation canals. In natural channels, such as rivers, approximate uniform flow is often assumed. This condition occurs when the channel’s bottom slope matches the energy slope, balancing potential energy lost from gravity with head loss due to shear stress. This balance prevents depth changes along the channel length, resulting in a steady, uniform flow.Uniform flow in open channels with a constant cross-section...
168