基于变压器的检测和临床评估系统,用于扭曲性阴
Ju-Hyuck Han1, Yong-Suk Kim1, Jong Bin Lee2
1Department of Artificial Intelligence, Konyang University, Daejeon 32992, Republic of Korea.
Sensors (Basel, Switzerland)
|July 12, 2025
概括
一种新的扭转变压器模型准确地检测了在患有良性发性定位 (BPPV) 的患者中扭转性静止痛. 这种人工智能系统增强了对微妙眼动的诊断能力,改善了临床决策.
科学领域:
- 眼科医生 眼科 眼科
- 神经学 神经学
- 医疗成像医学成像
背景情况:
- 良性发性定位性 (BPPV) 诊断依赖于对扭曲性阴囊的准确评估.
- 传统的视频阴影影像 (VNG) 难以准确量化眼睛旋转动作.
- 现有的自动化方法在检测扭曲性阴囊的有效性有限.
研究的目的:
- 开发一套自动化系统,用于准确和定量检测扭曲性阴囊痛.
- 介绍扭转变压器模型,用于从虹膜图像直接估计扭转角度.
主要方法:
- 一个自我监督的学习框架与解码器和寻找器模块来估计扭矩角度.
- 时间序列扭矩角度数据由1D卷积神经网络 (1D-CNN) 分类器分析.
- 使用127名BPPV患者的视频记录进行评估.
主要成果:
- 扭转变压器实现了89.99%的灵敏度,86.36%的特异性,88.82%的F1得分和87.93%的AUROC.
- 性能与水平和垂直阴囊检测的既定方法相提并论.
- 该模型有效地量化了扭曲性阴茎.
结论:
- 扭转变压器在扭转性静止痛检测方面取得了显著的技术改进.
- 该系统显示出作为BPPV诊断临床决策支持工具的前景.
- 提高医疗保健专业人员的诊断准确度.
更多相关视频
11:06Bilateral Assessment of the Corticospinal Pathways of the Ankle Muscles Using Navigated Transcranial Magnetic Stimulation
Published on: February 19, 2019
8.7K
08:57Measuring the Influence of Magnetic Vestibular Stimulation on Nystagmus, Self-Motion Perception, and Cognitive Performance in a 7T MRT
Published on: March 3, 2023
2.0K
相关概念视频
Potentiometer
Voltage and current measurements using a standard voltmeter and ammeter alter the circuit being measured either by drawing or resisting the current flow, which introduces uncertainties in the measurements. Null measurements balance the voltages so that no current flows through the measuring device and, therefore, no alterations occur in the measured circuit.
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
Amperometry: Overview
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
Instrumentation Amplifier
An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Instrument Transformers
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
Differential Relays
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
Turbine-Governor Control
Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
