参数识别和过渡过程 在线校准方法,基于低压动态响应特征的脉冲流接收线圈
Zhiwu Zeng1, Jie Wang1, Xiaoju Huang1
1Construction Branch State Grid Jiangxi Electric Power Co., Ltd., Nanchang 330036, China.
Sensors (Basel, Switzerland)
|July 12, 2025
概括
这项研究引入了一种用于脉冲流 (PEC) 系统的新方法,以准确识别接收线圈参数. 这提高了PEC检测信号的精度和整体系统准确度.
科学领域:
- 电磁主义 电磁主义
- 非破坏性测试 不破坏性测试
背景情况:
- 脉冲旋流 (PEC) 系统在检测过程中容易受到系统参数偏移的影响.
- 准确的系统参数识别对于可靠的PEC信号分析和解卷是至关重要的.
研究的目的:
- 开发一种方法来准确识别脉冲流接收线圈参数.
- 提高PEC系统的解卷精度和整体检测精度.
主要方法:
- 对接收系统响应信号和解卷过程的分析.
- 通过激发线圈应用一个步骤信号来改变系统响应特征,用于参数识别.
- 使用牛顿方法来准确识别接收系统.
- 研究匹配电阻和并行电容器切换对识别准确性的影响.
主要成果:
- 拟议的方法有效且准确地识别接收线圈的参数.
- 模拟和实验结果验证了参数识别技术的有效性.
- 证明了PEC检测信号的反转精度的改善.
结论:
- 开发的方法为脉冲流接收线圈参数识别提供了一种高效,方便和准确的方法.
- 这种技术显著提高了PEC检测和信号逆转的准确性.
更多相关视频
06:17Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
5.8K
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.8K
相关概念视频
Magnetic Damping
560
Eddy currents can produce significant drag on motion, called magnetic damping. For instance, when a metallic pendulum bob swings between the poles of a strong magnet, significant drag acts on the bob as it enters and leaves the field, quickly damping the motion.
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
560
Eddy Currents
1.7K
Since eddy currents occur only in conductors, magnets can separate metals from other materials. For example, in a recycling center, trash is dumped in batches down a ramp, beneath which lies a powerful magnet. Conductors in the trash are slowed by eddy currents, while nonmetals in the trash move on, separating from the metals. This works for all metals, not just ferromagnetic ones.
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
1.7K
Calculation of Self-inductance
461
The self-inductance of a circuit, often simply called the inductance, is a purely geometric factor that depends only on the circuit component's structure. More specifically, it depends on the shape and size of the component that lets the flux pass through it, thus inducing an electric field that opposes any current passing through it.
Since the effect of the induced electric field and the back EMF generated depends on the rate of change of current and the self-inductance, the inductance...
Since the effect of the induced electric field and the back EMF generated depends on the rate of change of current and the self-inductance, the inductance...
461
Design Example: Underdamped Parallel RLC Circuit
380
Consider designing an oscillator circuit, a crucial component in various electronic devices and systems. The objective is to create an oscillator circuit with specific characteristics: a damped natural frequency of 4 kHz and a damping factor of 4 radians per second. To accomplish this, a parallel RLC circuit is employed, known for its ability to sustain oscillations at a resonant frequency. In this case, the damping factor is pivotal in achieving the desired performance.
Starting with a fixed...
Starting with a fixed...
380
Magnetic Field Of A Current Loop
5.0K
Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
5.0K
Controlled-Current Coulometry: Overview
308
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
308