相关实验视频
Updated: Sep 16, 2025

08:20
In Situ Soil Moisture Sensors in Undisturbed Soils
Published on: November 18, 2022
6.6K
混合传感器网络中的覆盖孔恢复基于紧急通信的关键感知交叉点
He Li1,2, Shixian Sun1, Chuang Dong2
1Henan Intelligent Emergency Service and Security Engineering Research Center, Nanyang Normal University, Nanyang 473061, China.
Sensors (Basel, Switzerland)
|July 12, 2025
概括
本研究引入了一种用于检测和恢复无线传感器网络 (WSN) 覆盖漏洞的新方法. 该方法优化了能源消耗,并通过智能管理传感器节点来改善网络覆盖率.
科学领域:
- 计算机科学 计算机科学
- 网络工程 网络工程
- 无线通信无线通信
背景情况:
- 无线传感器网络 (WSNs) 面临着能源耗尽的挑战,导致覆盖孔和性能降低.
- WSN 中的覆盖漏洞损害了数据质量,网络效率和整体服务质量.
- 有效地检测和恢复覆盖孔对于可靠的WSN运行至关重要.
研究的目的:
- 提出一种有效的方法来检测和恢复无线传感器网络中的覆盖孔.
- 解决因覆盖孔造成的能源耗尽和网络功能障碍的问题.
- 通过改进覆盖管理,提高WSN的性能和可靠性.
主要方法:
- 拟议的方法将WSN划分为单位,并选择代表性代理节点.
- 覆盖率的百分比是准确计算,以检测覆盖孔.
- 粒子集群优化 (PSO) 用于洞恢复,使用关键感知交叉点作为初始值.
主要成果:
- 该算法将网络能耗降低了6.68%.
- 移动节点所行驶的距离减少了8.51%.
- 与现有算法相比,网络漏洞恢复的百分比增加了2.16%.
结论:
- 开发的方法有效地检测和恢复WSNs中的覆盖孔.
- 这种方法可以显著提高能源效率和网络覆盖率.
- 这种技术为提高无线传感器网络的寿命和性能提供了一个有希望的解决方案.
相关概念视频
Applications of GIS: Disaster Management and Emergency Response
157
Geographic Information System (GIS) technology is essential for risk identification, action prioritization, and resource optimization in critical situations like flooding and earthquakes. By integrating spatial and demographic data, GIS provides a comprehensive framework for emergency response.GIS integrates data layers, like rainfall intensity, topography, elevation profiles, and river levels, to model high-risk flood zones. These layers assess areas susceptible to flooding based on their...
157
Reclosers and Fuses
166
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
166
Zones of Protection
351
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
351
Elastic Collisions: Case Study
14.3K
Elastic collision of a system demands conservation of both momentum and kinetic energy. To solve problems involving one-dimensional elastic collisions between two objects, the equations for conservation of momentum and conservation of internal kinetic energy can be used. For the two objects, the sum of momentum before the collision equals the total momentum after the collision. An elastic collision conserves internal kinetic energy, and so the sum of kinetic energies before the collision equals...
14.3K
Line Protection with Impedance Relays
136
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
136
Overcurrent Relays
166
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...