电图和声图信号的同步获取和处理,以准确测量心缩时间,用于心脏病诊断和监测
Roberto De Fazio1,2, Ilaria Cascella1, Şule Esma Yalçınkaya1
1Department of Innovation Engineering, University of Salento, Road to Monteroni, Building 'O', 73100 Lecce, Italy.
Sensors (Basel, Switzerland)
|July 12, 2025
概括
这项研究引入了一种结合心电图 (ECG) 和心声图 (PCG) 的新方法,以更好地监测心血管疾病. 开发的算法准确地提取了关键的心脏参数,提高了诊断潜力.
科学领域:
- 生物医学工程 生物医学工程
- 心脏病学 心脏病学
- 信号处理 信号处理
背景情况:
- 心血管疾病是全球死亡的主要原因之一.
- 电心电图 (ECG) 是心脏电活动的标准,但对于像门疾病这样的疾病是不够的.
- 声心电图 (PCG) 分析心脏声音,在与心电图相结合时提高诊断准确性.
研究的目的:
- 开发和验证用于同时采集和分析ECG和PCG信号的方法.
- 为心血管疾病监测提取关键缩时间间隔 (EMAT,PEP,LVET,LVST).
- 评估开发的自适应细分算法的可靠性和稳定性.
主要方法:
- 同时采集ECG和PCG信号,使用一个带有AD8232模拟前端和数字耳语镜的紧型系统.
- 在胸部放置心电图电极和麦克风,以实现空间信号对齐.
- 开发一种自适应细分算法,以识别关键波 (Q,R,S) 和心声 (S1,S2) 进行参数提取.
主要成果:
- 测量的平均缩时间间隔 (EMAT,PEP,LVET,LVST) 与参考标准一致.
- 该算法在不同记录条件下表现出稳定性,提取的间隔与文献值密切匹配.
- 在BSSLAB本地化ECG数据数据集上的验证证实了该方法的可靠性.
结论:
- 联合ECG和PCG分析显示了改善长期心血管疾病监测的巨大潜力.
- 开发的自适应细分算法可以准确地提取重要心血管参数.
- 这种综合方法为改善心脏诊断和患者管理提供了有前途的工具.
相关概念视频
Pulse rhythm
933
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
933
Electrocardiogram
3.2K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
3.2K
Correlation between ECG and Cardiac Cycle
8.4K
The electrical signals recorded on an electrocardiogram (ECG) occur before the mechanical processes of contraction and relaxation during the cardiac cycle.
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
8.4K
Imaging Studies for Cardiovascular System I:Echocardiography
492
Cardiac imaging studies encompass a wide range of noninvasive and minimally invasive techniques designed to visualize the heart's structure and function in detail. One such technique is echocardiography, which uses high-frequency ultrasound waves to produce detailed images of the heart, known as echocardiograms.
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
492
Holter Monitor: 24-Hour Monitoring
295
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
295
Equipments Used To Measure Blood Pressure
2.4K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.4K