六起集体闪电引发的电弧爆炸伤害案例:一个案例报告
Huan Xiao1, Ying Qiu1, Yong Li1
1Department of Emergency, The First Affiliated Hospital of Guangxi Medical University, 6 Shuangyong Road, Nanning 530021, China.
The American journal of emergency medicine
|July 13, 2025
概括
这项研究详细介绍了一个罕见的闪电弧爆炸事件,影响了六个人. 它强调了环境因素,如肺伤和记忆丧失等直接伤害,以及对这些复杂的电损伤的有效治疗方法.
科学领域:
- 环境医学 环境医学
- 创伤学 创伤学 创伤学
- 电气损伤研究 电气损伤研究
背景情况:
- 对大规模闪电损伤机制和临床表现的理解有限.
- 专注于现有文献中的单个患者病例研究.
- 需要对同时发生的局部闪电事件进行全面分析.
研究的目的:
- 报告环境状况,受伤情况和6名患者的治疗情况,这些患者同时受到闪电引起的弧形爆炸伤害.
- 阐明局部,多人闪电伤害的机制和多系统临床特征.
主要方法:
- 一系列案例报告了6名患者因闪电引起的电弧爆炸而受伤.
- 对环境因素,伤害类型,实验室发现 (hs-CRP,白细胞病,低血) 和心电图 (ECG) 异常的分析.
- 治疗方案的文件,包括抗生素,高压氧和支持性护理.
主要成果:
- 在200米半径内的6名患者同时受到弧形爆炸伤害.
- 常见的伤害包括意识丧失,记忆障碍,肺伤,低血量,炎症标志物升高,白细胞症和异常心电图.
- 四名患者出现了皮肤烧伤和耳膜穿孔;那些穿着雨衣的人受到这些特定伤害的保护.
结论:
- 闪电弧爆炸损伤具有复杂的,多系统的临床特征.
- 环境因素和防护装备 (雨衣) 影响了受伤模式.
- 迅速,有症状的支持性治疗导致在八天内康复和出院.
- 强调实施强有力的防雷措施至关重要.
相关概念视频
Burn Injuries
2.9K
Burn injuries occur when the skin and underlying tissues are damaged due to exposure to heat, electricity, chemicals, radiation, or friction. They can vary in severity, from minor superficial burns to severe deep burns that can be life-threatening.
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
2.9K
Power System Three-Phase Short Circuits
150
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
150
Circuit Breaker and Fuse Selection
147
A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems,...
In high-voltage systems,...
147
Insulation Coordination
232
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
232
Fault Types
128
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
128
Household Wiring And Electrical Safety
1.4K
Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.4K