数字病理学和光显微镜之间的变化,用于诊断组织病理学幻灯片:盲目交叉比较研究
David Rj Snead1,2, Ayesha S Azam1,2, Jenny Thirlwall2
1Histopathology, University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK.
数字病理学提供了与传统光显微镜相提并论的诊断准确性,用于组织病理学幻灯片报告. 这项研究发现临床管理一致性超过了99.95%,证明了数字病理学在常规实践中的可靠性.
科学领域:
- 数字病理学和组织病理学成像.
- 医疗诊断和报告.
背景情况:
- 数字病理学将组织病理学幻灯片转换为数字文件,用于计算机分析.
- 评估数字病理学与光显微镜的诊断等价性对于采用至关重要.
- 目前的护理标准依赖于明亮场和免疫光光显微镜.
研究的目的:
- 为了将数字病理与光显微镜进行比较,用于组织病理学幻灯片报告.
- 测量两种方法之间的病理学家内部和病理学家间的变化.
- 用数字病理学评估临床管理一致性.
主要方法:
- 一个多中心,盲目的交叉研究,涉及四个专业的2024例病例.
- 每个专业的四名病理学家对每个幻灯片进行了两次评估:一次用光显微镜,一次用数字病理学.
- 使用随机效应逻辑回归模型来估计临床管理一致性.
主要成果:
- 总体临床管理一致性为99.95%,超过了98.3%的参考值.
- 跨专业的一致性仍然很高:乳腺 (99.40%),胃肠道 (99.96%),皮肤 (99.99%) 和脏 (99.99%).
- 报告时间相似,病理学家越来越快地熟悉数字病理学;然而,光显微镜的诊断信心更高.
结论:
- 数字病理学证明了高临床管理一致性,相当于光显微镜.
- 该技术可靠用于跨多个专业的例行组织病理学报告.
- 对于在细胞学样本中的数字病理学应用,需要进一步的研究.
更多相关视频
07:52Multiplexed Fluorescent Immunohistochemical Staining, Imaging, and Analysis in Histological Samples of Lymphoma
Published on: January 9, 2019
06:47Expanding the Comprehension of the Tumor Microenvironment using Mass Spectrometry Imaging of Formalin-Fixed and Paraffin-Embedded Tissue Samples
Published on: June 29, 2022
相关概念视频
Two-Dimensional Microscopy in Microbiology
Three-Dimensional Microscopy in Microbiology
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Overview of Microscopy Techniques