来自巴拉圭国家互联系统和气象数据集的电力需求
Félix Morales-Mareco1, Matías Verdún1, Diego H Stalder1
1Facultad de Ingeniería, Universidad Nacional de Asunción, San Lorenzo 111421, Paraguay.
Data in brief
|July 14, 2025
概括
这项研究将巴拉圭国家互联系统 (SIN) 的每小时电力需求数据与气象记录相结合. 综合数据集能够对能源消耗模式进行详细分析,并支持改进能源管理.
科学领域:
- 能源系统分析 能源系统分析
- 气象学 天气学
- 数据科学数据科学数据科学
背景情况:
- 了解电力需求驱动因素对于电网稳定至关重要.
- 巴拉圭国家互联系统 (SIN) 需要可靠的数据来实现运营效率.
- 长期的气象数据对于预测能源消耗变化至关重要.
研究的目的:
- 提出一个综合数据集,整合巴拉圭每小时的电力需求和气象数据.
- 促进对电力消费趋势和模式的详细分析.
- 支持能源预测模型的开发,优化能源管理.
主要方法:
- 从巴拉圭国家电力管理局 (ANDE) 收集的每小时电力需求数据.
- 从全球数据同化系统 (GDAS) 每隔三小时获得的气象数据 (温度,湿度).
- 从2008年到2022年的综合数据集用于长期分析.
主要成果:
- 已经编制了巴拉圭 (2008-2022) 每小时电力需求和气象变量的综合数据集.
- 该数据集允许详细检查天气条件和电力消耗之间的关系.
- 高频数据允许进行深入的趋势和模式分析.
结论:
- 综合数据集是巴拉圭研究人员和电网运营商的宝贵资源.
- 它支持对电力需求的增强预测,这对电网稳定至关重要.
- 数据可以为能源分配优化,基础设施规划和效率改进提供信息.
相关概念视频
Precipitation and Co-precipitation
2.1K
Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
2.1K
Electrical Power
3.2K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.2K
Maximum Power Flow and Line Loadability
184
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
184
Power System Distribution
319
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
319
Precipitation Processes
604
The experimental conditions in a gravimetric analysis should be optimized to maximize the particle size and purity of the obtained precipitate. Ideally, the concentration of the precipitating reagent should be low with effective stirring to maintain low relative supersaturation for the growth of large crystals. In homogeneous precipitation, the precipitant is slowly generated by a chemical reaction in the solution to avoid local reagent excesses. For example, urea decomposes gradually to...
604
Secondary Distribution
140
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
140