设计和验证用于电阻断层扫描的多角度平面电极系统
Busra Oguzhan1, Mustafa Istanbullu2
1Department of Electrical and Electronics Engineering, Kahramanmaras Sutcu Imam University, Kahramanmaras, Turkey.
Physical and engineering sciences in medicine
|July 16, 2025
概括
这项研究引入了一种新的生物阻抗测量系统,用于非侵入性成像的同心环电极. 该系统增强了空间分辨率和实际应用,用于在没有辐射的情况下检测内部组织异常.
科学领域:
- 生物医学工程 生物医学工程
- 医疗成像医学成像
- 电气工程 电气工程
背景情况:
- 基于电阻的成像提供了对内部组织的非侵入性,无辐射的评估.
- 传统的电阻断层扫描 (EIT) 在空间分辨率和实用性方面存在局限性.
研究的目的:
- 提出和验证一种具有平面同心环电极配置的新型生物阻抗测量 (BIM) 系统.
- 与传统的EIT相比,提高空间分辨率和实用性.
主要方法:
- 一个32个电极系统与四个同心环被设计为多角度电流注入和电压测量.
- 为了验证,使用EIDORS进行模拟和使用盐水进行实验测试.
- 图像重建采用高斯-牛顿算法与总变异规范化和图像处理.
主要成果:
- 模拟成功地局部化了内部不均性.
- 实验测试证实了该系统在检测嵌入物体方面的有效性.
- 该系统展示了强大的测量和图像重建能力.
结论:
- 拟议的BIM系统为生物医学诊断提供了具有成本效益,便携性和准确性的解决方案.
- 它显示了需要非侵入性监测的临床和非临床应用的潜力.
- 该系统通过改进的空间分辨率提高了局部异常的检测.
相关概念视频
Electric Field of Parallel Conducting Plates
Gauss' law relates the electric flux through a closed surface to the net charge enclosed by that surface. Gauss's law can be applied to find the electric field and the charge enclosed in a region depending on its charge distribution.
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
The Electrical Double Layer
In the region where two bulk phases meet, an intricate electric charge distribution arises due to charge transfer, ion adsorption, molecular orientation, and charge distortion. This complex distribution is commonly referred to as the electrical double layer.When a solid electrode interfaces with ions in an electrolyte solution, the speed of electron transfer dictates the rates of oxidation and reduction. The electrode acquires a charge through the escape of atoms into the solution as cations or...
Radial System Protection
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Line Protection with Impedance Relays
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...