Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Redox Titration: Iodimetry and Iodometry01:23

Redox Titration: Iodimetry and Iodometry

2.7K
Iodometry and iodimetry are analytical methods used to determine the concentration of oxidizing or reducing agents using iodine. In iodometric titrations, the oxidizing analyte solution is usually acidified and treated with an excess of iodide ions, which generates an equivalent amount of iodine in equilibrium with triiodide. The released iodine is subsequently titrated directly against a standardized reducing agent. As the dilute iodine color becomes pale yellow, a few drops of freshly...
2.7K
Computed Tomography01:10

Computed Tomography

6.3K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
6.3K
Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

418
Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and...
418

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Integrative analysis prioritizes proteins associated with renal cell carcinoma and its risk factors.

JNCI cancer spectrum·2026
Same author

Large distant deletion disrupts CDKN2A enhancer and predisposes to melanoma.

medRxiv : the preprint server for health sciences·2026
Same author

A multi-modal flow phantom for quantitative PET/Spectral CT.

bioRxiv : the preprint server for biology·2026
Same author

Recurrent ZC3H18 mutations stabilize oncogenic endogenous retroviral RNA.

Cell reports·2026
Same author

GWAS meta-analysis provides new insights into uveal melanoma risk.

British journal of cancer·2026
Same author

Disruption of CTCF binding by germline non-coding variants in <i>CDKN2B</i> suppress <i>CDKN2A</i> expression and predispose to melanoma.

medRxiv : the preprint server for health sciences·2026

相关实验视频

Updated: Sep 14, 2025

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

427

有效的光谱数据减少,用于在多能CT中准确量化.

Olivia F Sandvold1,2, Roland Proksa3, Heiner Daerr4

  • 1Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA. Sandvold@upenn.edu.

Scientific reports
|July 18, 2025
PubMed
概括

本研究引入了一种用于多通道计算机断层扫描 (CT) 的光谱数据减少方法,使用优化的双通道权重. 这种方法保持了材料分解的准确性,同时大大降低了临床应用的噪音和计算复杂性.

关键词:
计算机断层扫描 (CT) 扫描在DECT中检测.的对比度是的对比度.多种能量CT多种能量CT定量成像成像技术的使用.频谱CT CT 的情况.kVp-切换的使用方法

更多相关视频

DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis
12:39

DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis

Published on: September 28, 2021

3.4K
Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
02:09

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function

Published on: April 12, 2024

681

相关实验视频

Last Updated: Sep 14, 2025

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

427
DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis
12:39

DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis

Published on: September 28, 2021

3.4K
Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
02:09

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function

Published on: April 12, 2024

681

科学领域:

  • 医学成像物理 医学成像物理
  • 辐射科学 辐射科学
  • 计算成像技术的成像

背景情况:

  • 多通道光谱计算机断层扫描 (CT) 提供了定量评估,但面临着噪声和计算负载的挑战.
  • 现有的光谱CT方法需要复杂的数据处理,限制了广泛的临床采用.

研究的目的:

  • 开发和验证用于多通道CT的光谱数据减少方法.
  • 为了优化材料分解的准确性,并最大限度地减少临床使用的数据复杂性.

主要方法:

  • 开发了一个新的权重方案,将四个光谱通道减少到两个优化的输入通道.
  • 使用Cramer-Rao下界来优化重量,以最大限度地减少和水分解中的噪声.
  • 模拟包括各种工作周期和患者大小 (150毫米,300毫米,400毫米的幻影).
  • 性能与全四通道和传统的快速kVp切换 (kVp-S) CT配置进行了比较.

主要成果:

  • 两个输入加权的方案表明噪声性能在0.27%的理想的四个输入结果在一个标准的成人幻影.
  • 在儿科和大成人幻影尺寸中,两输入方案的平均差异低于1%与理想的四输入噪声估计相比.
  • 拟议的方法始终与经过测试的配置中的四通道设置的准确性相匹配.

结论:

  • 优化的双通道权重有效地减少了光谱CT中的数据复杂性.
  • 这种方法的准确性与材料分解的四通道设置相美.
  • 该方法显著降低噪声和计算需求,提高光谱CT的临床适用性.