基于交叉的AC系列电弧故障检测用于更多电动飞机
Sina Hosseini1,2, Iman Sadeghkhani3,4
1Smart Microgrid Research Center, Najafabad Branch, Islamic Azad University, Najafabad, 85141-43131, Iran.
Scientific reports
|July 18, 2025
概括
本研究引入了一种新的方法,用于检测更多电气飞机 (MEA) 中的AC系列弧断,使用电流波形分析. 该技术可靠地识别这些危险故障,提高飞机电气系统的安全性.
科学领域:
- 电气工程 电气工程
- 航空航天工程 航空航天工程
- 电力系统 电力系统
背景情况:
- 越来越多的电气飞机 (MEA) 系统在电气系统可靠性和安全性方面面临挑战.
- 由于火灾危险和系统退化,AC系列弧形故障在MEA是一个重要的风险.
- 由于它们的间歇性和与正常事件相似,因此很难检测这些故障.
研究的目的:
- 为MEA提出一种新的AC系列电弧故障检测技术.
- 提高新一代飞机机上的机载电气系统的安全性和保护.
主要方法:
- 使用时间域当前波形分析.
- 使用交叉度量化弧线断层不对称.
- 提取故障的组件,以获得检测指数.
- 随着时间的推移,监测故障组件的能量.
主要成果:
- 拟议的技术在检测交流电系列弧故障方面表现出高灵敏度和可靠性.
- 有效地歧视非故障干扰,如负载切换和非线性负载.
- 通过广泛的模拟和灵敏度分析证实了强度.
结论:
- 开发的技术为检测MEA中的AC系列弧断提供了一个有希望的解决方案.
- 有助于提高飞机电气系统的安全性和可靠性.
- 解决了检测间歇性和暂时性弧形故障的挑战.
相关概念视频
Three-Phase Short Circuit—Unloaded Synchronous Machine
237
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
237
Power System Three-Phase Short Circuits
150
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
150
Series R—L Circuit Transients
155
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
155
Circuit Breaker and Fuse Selection
147
A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems,...
In high-voltage systems,...
147
Reclosers and Fuses
163
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
163
Fault Types
127
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
127