旋转机烧孔断开和一个差距预测器
Kazunori Yamaji1, Kota Tanaka1, Tomohiro Yamasaki1
1Cardiovascular Center, Sakurabashi Watanabe Advanced Healthcare Hospital, Osaka, Japan.
JACC. Case reports
|July 19, 2025
概括
旋转性心脏切除术 (Rotablator) 孔断路是一种罕见的并发症. 在断开连接之前观察到一个"空白标志"的空隙可能会表明需要停止程序并检查设备.
科学领域:
- 心血管干预 心血管干预
- 医疗器械并发症 医疗器械并发症
- 干预心脏病学 干预心脏病学
背景情况:
- 旋转性心脏切除术是治疗复杂冠状动脉疾病的关键手术.
- 子与驱动轴的断开是非常罕见但严重的并发症.
- 了解口断路的原因和预测因素对于患者的安全至关重要.
更多相关视频
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
28.0K
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
10.6K
相关概念视频
Node Analysis for AC Circuits
376
Consider an angioplasty system featuring a catheter equipped with a turbine, a critical tool for removing plaque deposits from coronary arteries. This intricate medical device operates using a circuit model reminiscent of a dual-node RLC circuit powered by a current-controlled voltage source.
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
376
Radial System Protection
149
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
149
Reclosers and Fuses
163
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
163