在多源信息融合下自动嵌入式变压器,用于几次射击故障诊断
Bo Wang1, Shuai Zhao2, Qian Zhao3
1School of Information and Artificial Intelligence, Nanchang Institute of Science & Technology, Nanchang, 330108, China.
Scientific reports
|July 19, 2025
概括
这项研究介绍了EDformer,这是一种用于几次射击故障诊断的新型变压器. 它有效地融合了多个来源的信息,提高了准确性和稳定性,即使数据有限.
科学领域:
- 机械工程 机械工程
- 人工智能的人工智能
- 机器学习 机器学习
背景情况:
- 智能故障诊断对于机械系统可靠性至关重要.
- 有限的标记数据和不良的多源信息融合阻碍了当前的方法.
- 现有的框架由于数据稀缺而难以准确.
研究的目的:
- 提出EDformer,一个自动嵌入式变压器用于几次拍摄故障诊断.
- 为了应对有限样本和多来源信息融合的挑战.
- 提高机械系统的诊断准确性和稳定性.
主要方法:
- 开发了一种新的编码解码器,用于从多源数据中进行高质量的嵌入式提取.
- 实现了使用变压器网络的交叉关注架构,以实现高效的多模式数据集成.
- 集成的全球最大聚合和全球平均聚合,以优化特征抽象.
主要成果:
- 与当代方法相比,EDformer表现出更高的分类准确性和稳定性.
- 该框架尤其在数据稀缺的情况下表现出色.
- t-SNE和ROC曲线可视化证实了有效的断层类别区分和特征捕获.
结论:
- EDformer提供了一种有效的解决方案,用于使用有限的多源数据进行短时间故障诊断.
- 拟议的方法增强了特征提取和数据集成,以提高诊断性能.
- 对于需要强大的故障诊断的真实世界工程应用,EDformer显示出巨大的潜力.
相关概念视频
Power System Three-Phase Short Circuits
150
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
150
Bus Impedance Matrix
178
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
178
Reducing Line Loss
195
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
195
Fault Types
127
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
127
Multi-input and Multi-variable systems
150
Cruise control systems in cars are designed as multi-input systems to maintain a driver's desired speed while compensating for external disturbances such as changes in terrain. The block diagram for a cruise control system typically includes two main inputs: the desired speed set by the driver and any external disturbances, such as the incline of the road. By adjusting the engine throttle, the system maintains the vehicle's speed as close to the desired value as possible.
In the absence...
In the absence...
150
Transformers in Distribution System
159
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
159


