相关实验视频
Updated: Sep 14, 2025

07:24
Home-Based Monitor for Gait and Activity Analysis
Published on: August 8, 2019
6.8K
在患有多发性硬化症的人中持续监测膀功能障碍:膀可穿戴设备
Valerie J Block1,2, Shane Poole1, Leah McIntyre2
1Department of Neurology, Weill Institute for Neurosciences, University of California San Francisco, San Francisco, California, USA.
Annals of clinical and translational neurology
|July 22, 2025
概括
对于患有多发性硬化症 (MS) 的人来说,远程膀超声监测是可行的. 这项技术捕捉了真实世界的膀症状变化,改善了与MS相关的膀功能障碍的评估和护理.
科学领域:
- 神经学 神经学
- 生物医学工程 生物医学工程
- 泌尿器科 泌尿器科 泌尿器科 泌尿器科
背景情况:
- 超过85%的多发性硬化症患者 (PwMS) 经历了膀功能障碍.
- 目前的评估方法有限,无法捕捉现实世界的症状波动.
研究的目的:
- 评估一种新型远程膀超声波装置的可行性和有效性,用于在PwMS中在家监测膀功能障碍.
- 将远程测量与标准临床评估进行比较.
主要方法:
- 一项为期3个月的试点研究,涉及22名MS妇女,在家中使用可穿戴超声波设备.
- 与临床数据 (cPVR,3天膀日记) 进行远程空虚后残留 (rPVR) 和尿动频率 (rFrequency) 的比较.
- 使用布兰德-阿尔特曼分析和相关系数评估的协议.
主要成果:
- 很高的研究保留率 (86.4%) 和设备使用率 (14.1天).
- 远程和临床空白后残留测量之间的良好一致性.
- 远程和患者报告的尿动频率之间存在强烈的相关性 (ICC=0.81,r=0.793).
- 远程监测显示了显著的一天到一天的症状变化.
结论:
- 可穿戴式超声波技术是可行的,并且在PwMS中对膀功能障碍的远程监测具有初步有效性.
- 捕捉现实世界的症状变化可以改变评估和管理.
- 能够为MS患者提供更加个性化和响应性的护理策略.
更多相关视频
06:49Evaluation of a Smartphone-based Human Activity Recognition System in a Daily Living Environment
Published on: December 11, 2015
9.0K
10:07Cystometric and External Urethral Sphincter Measurements in Awake Rats with Implanted Catheter and Electrodes Allowing for Repeated Measurements
Published on: January 30, 2018
16.1K
相关概念视频
Holter Monitor: 24-Hour Monitoring
292
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
292
Pulse rhythm
931
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
931
Urinary Bladder
1.5K
The urinary bladder is a hollow, muscular sac that temporarily stores urine before it is expelled from the body. It can hold approximately 600 mL of urine prior to micturition. The bladder is retroperitoneal and located behind the pubic symphysis in the pelvic floor.
In males, the bladder is situated in front of the rectum, while in females, it is positioned anterior to the vagina and uterus. The bladder floor contains an inverted triangular area called the trigone, defined by the two ureteric...
In males, the bladder is situated in front of the rectum, while in females, it is positioned anterior to the vagina and uterus. The bladder floor contains an inverted triangular area called the trigone, defined by the two ureteric...
1.5K