湿,广

Tongkuai Li1, Tingting Zhao1, Li Yuan1

  • 1Key Laboratory of Advance Display and System Applications, Ministry of Education, Shanghai University, Shanghai, 200072, China.

概括

这项研究引入了一种新的湿度敏感突触晶体管,模仿人类视觉识别. 这种可适应的神经形态系统在不同的环境条件下增强了机器人的感知能力.

相关概念视频

Bipolar Junction Transistor01:22

Bipolar Junction Transistor

Bipolar Junction Transistors (BJTs) are essential elements in electronic circuits, playing a crucial role in the functionality of amplifiers, memories, and microprocessors. These transistors can be designed as NPN or PNP based on their doping patterns. They consist of three layers: the emitter, base, and collector. The configuration of these layers and their respective doping levels—with N-type or P-type impurities—define the transistor's type and its operational...
928
Field Effect Transistor01:29

Field Effect Transistor

Field-effect transistors (FETs) are integral to electronic circuits and distinguished by their three-terminal setup: the gate, drain, and source. These transistors operate as unipolar devices, which utilize either electrons or holes as charge carriers, in contrast to bipolar transistors, which use both types of carriers. The primary function of the FET is to modulate the flow of these carriers from the source to the drain through a channel. The voltage difference between the gate and source...
570
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
2.1K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
794