使用新型分析算法的振动控制过渡弹性质谱的质量改进
Jeffrey Schwartz1, Shalini Tripathi2, Omar T Sims3
1Department of Gastroenterology and Hepatology, Cleveland Clinic Foundation. Cleveland, OH, USA.
概括
用于振动控制的短暂弹性图 (VCTE) 的新概率算法改善了对各种肝脏疾病的肝纤维化评估. 提供者反表明更好的理解和沟通,特别是当VCTE和活检结果不同时.
科学领域:
- 肝病学 肝病学是一种肝病学.
- 医疗成像医学成像
- 生物统计学 生物统计学
背景情况:
- 通过VCTE进行肝硬度 (LS) 评估,由于诊断设备和各种纤维化病因而面临局限性.
- 开发了一种新的概率报告算法,以解决VCTE输出中的这些局限性.
- 收集了提供者对这种肝病分层新框架的反.
研究的目的:
- 为VCTE输出设计和评估一种新的概率报告算法,根据肝病病因分层.
- 与传统方法相比,评估医疗保健提供者的经验和对这种新算法的看法.
- 用VCTE提高肝纤维化病阶段的准确性和清晰度.
主要方法:
- 通过重新分析Baveno VI弹性学标准研究的最佳切断值,创建了一个概率算法.
- VCTE输出被转换为根据病因分层的肝纤维化阶段 (F0-F4) 的概率 (MASLD,B型肝炎,C型肝炎,酒精性肝病).
- 一项调查评估了肝病学提供者的新算法经验,重点关注理解,沟通和患者体验.
主要成果:
- 概率算法于2023年3月在克利夫兰诊所的VCTE输出中实施.
- 与传统算法相比,提供商调查表明,与新算法相比,新算法的经验更为有利.
- 该算法有助于更好地了解纤维化,与医生沟通和患者沟通,特别是当VCTE和活检结果不一致时.
结论:
- 新的概率算法承认LS与组织纤维化相关的局限性,特别是在中间值.
- 提供者报告说,当VCTE和活检结果不一致时,患者的护理经验得到改善,患者的治疗结果得到改善.
- 需要进一步改进,以优化患者对VCTE测试结果的理解.
相关概念视频
¹H NMR: Interpreting Distorted and Overlapping Signals
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Mass Spectrum: Interpretation
An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
Mass Analyzers: Overview
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Mass Analyzers: Common Types
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Mass Spectrometry: Complex Analysis
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...