概括
这项研究引入了一种新的技术,用于在静脉动脉外体膜氧化 (VA ECMO) 后去除大管. "预和后固定技术"在关闭动脉切除部位方面取得了100%的成功,没有并发症.
科学领域:
- 心血管外科心血管外科
- 身体外生命支持器
- 血管接入管理系统
背景情况:
- 周围静脉动脉 (VA) 外体膜氧化 (ECMO) 解管可以导致伪动脉瘤和出血由于动脉切除部位扩大.
- 标准的关闭技术,比如两个ProGlide法,在长时间的VA ECMO支持后,对于大管通常是不够的.
研究的目的:
- 引入和评估一项用于外围VA ECMO断管的新型"预和后定技术".
- 评估这种新技术在经过ECMO后管理大动脉切除部位的有效性和安全性.
主要方法:
- 一个回顾性分析的五个案例使用的"预和后安全技术"为VA ECMO脱管.
- 这种技术涉及在ECMO取管之前预先结结和固定,并在取管时收紧.
主要成果:
- 该技术在所有五个案例中都显示出100%的程序成功率.
- 没有观察到任何并发症,如伪动脉瘤形成或出血.
- 来自预先固的培养物没有显示细菌生长,也没有检测到血液感染.
结论:
- "预和后定技术"是外围VA ECMO断管的安全有效方法,特别是在大型管中.
- 这种新的方法可能会提高脱管成功率,并减少ECMO支持后与大型管部位相关的并发症.
相关概念视频
Cardiopulmonary Resuscitation II: ACLS Airway Management
97
Airway management is a key skill in emergency and critical care settings, as maintaining a clear airway is essential for adequate oxygenation and ventilation.Head Tilt-Chin Lift TechniqueThe head tilt-chin lift maneuver is an essential technique primarily used in patients without suspected cervical spine injuries. To perform this maneuver, one hand is placed on the patient’s forehead, and gentle pressure is applied backward to tilt the head. The fingertips of the other hand are positioned...
97
Tracheostomy Decannulation
394
Tracheostomy decannulation is a significant milestone in the liberation of mechanically ventilated patients. Despite its importance, there is no universally accepted protocol for this procedure. This demands an evidence-based, individualized approach.
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
394
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
584
Intravenous regional anesthesia or the Bier block technique is used to anesthetize a specific limb or extremity. It uses exsanguinated or blood-drained vessels to transport local anesthetics or LAs to the peripheral nerve trunks. Lidocaine without vasoconstrictors like epinephrine is most commonly used for this technique. Other drugs used are prilocaine, ropivacaine, and chloroprocaine. Bupivacaine is not recommended for this technique due to its high cardiac toxicity.
One of the advantages of...
One of the advantages of...
584
Tracheostomy Suctioning I: Pre-Procedural Steps
1.1K
Tracheostomy suctioning is a critical procedure healthcare professionals perform to maintain a patent airway in patients with a tracheostomy tube. This procedure is necessary when secretions accumulate in the airway, causing respiratory distress. Here is a step-wise procedural guide for performing tracheostomy suctioning using an open system.
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
1.1K
Endotracheal Intubation I: Procedure
3.1K
Endotracheal or ET intubation is a critical medical procedure used to secure a patient's airway, often in acute respiratory distress, apnea, upper airway obstruction, ineffective clearance of secretions, high risk for aspiration, or during general anesthesia.
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
3.1K