相关实验视频
Updated: Sep 13, 2025

10:09
Operation of the Collaborative Composite Manufacturing CCM System
Published on: October 1, 2019
6.7K
通过并行输电线和DGS的分支线联接器的新方法
Sadegh Heydari Kahkesh1, Akram Sheikhi2
1Electrical Engineering Department, Faculty of Engineering, Lorestan University, Khorramabad, 68151-44316, Iran.
Scientific reports
|July 28, 2025
概括
研究人员开发了一种超紧的3dB微带合器,使用螺旋传输线和有缺陷的地面结构 (DGS). 这种微型设计实现了75%的尺寸缩小,同时保持了RF应用的出色性能.
科学领域:
- 电气工程 电气工程
- 电磁学 电磁学 电磁学 电磁学
- 微波工程 微波工程
背景情况:
- 微条带合器是射频系统中必不可少的部件.
- 传统设计往往面临尺寸和集成方面的局限性.
- 微型化对于现代紧型电子设备至关重要.
研究的目的:
- 设计和验证一个超紧的3dB微带合器.
- 为了实现显著的尺寸缩小,同时保持高性能.
- 探索微波元件小型化的新技术.
主要方法:
- 利用具有螺旋结构的平行传输线路来优化空间.
- 整合了一个有缺陷的地面结构 (DGS) 来增强阻抗特性并减少足迹.
- 采用数学分析,全波模拟和实验原型设计进行验证.
主要成果:
- 与传统合器相比,实现了75%的尺寸缩小.
- 显示回报损失约为-15dB,分数带宽 (FBW) 为10.5%.
- 在广泛的频率范围内显示一致的相差.
结论:
- 拟议的设计提供了一个非常紧和高效的3dB微条带合器.
- 螺旋线和DGS的整合有效地解决了小型化的挑战.
- 这种设计适用于要求高度集成的先进无线通信和射频应用.
相关概念视频
Transmission Line Design Considerations
215
Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
215
Transmission-Line Differential Equations
404
Transmission lines are essential components of electrical power systems. They are characterized by the distributed nature of resistance (R), inductance (L), and capacitance (C) per unit length. To analyze these lines, differential equations are employed to model the variations in voltage and current along the line.
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured...
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured...
404
Line Protection with Impedance Relays
135
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
135
Series Impedances: Three-Phase Line
152
Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
152
Power System Three-Phase Short Circuits
150
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
150
Parallel RLC Circuits
1.0K
Street lamps equipped with RLC surge protectors are an excellent example of applying circuit analysis in practical scenarios. These surge protectors safeguard the lamp's components against sudden voltage spikes.
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
1.0K