Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Temperature Measurement Sites01:14

Temperature Measurement Sites

2.2K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
2.2K
Calorimetry01:19

Calorimetry

3.2K
When objects at different temperatures are placed in contact with each other but isolated from everything else, they attain thermal equilibrium. A container that prevents heat transfer in or out is called a calorimeter, and the use of a calorimeter to make measurements is called calorimetry. Generally, these measurements involve heat or specific heat capacity. The term "calorimetry problem" is used for any problem where the specified objects are thermally isolated from their...
3.2K
Instrument Calibration01:12

Instrument Calibration

269
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
269
Equipments Used to Measure Body Temperature01:13

Equipments Used to Measure Body Temperature

1.2K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.2K
Constant Pressure Calorimetry03:02

Constant Pressure Calorimetry

86.4K
Calorimetry is a technique used to measure the amount of heat involved in a chemical or physical process or to measure the heat transferred to or from a substance. The heat is exchanged with a calibrated and insulated device called the calorimeter. Calorimetry experiments are based on the assumption that there is no heat exchange between the insulated calorimeter and the external environment. The well-insulated calorimeters prevent the transfer of heat between the calorimeter and its external...
86.4K
Flame Photometry: Lab01:16

Flame Photometry: Lab

363
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
363

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Natto May Alleviate Retinoic Acid-Induced Osteoporosis by Activating Gut Microbiota-Bile Acid Axis and OPG/RANKL Signaling Pathway.

Nutrients·2026
Same author

Tunable Bessel beam two-photon fluorescence microscopy for high-speed volumetric imaging of brain dynamics.

eLife·2026
Same author

The selenium-enriched <i>Rhodotorula mucilaginosa</i> JAASRY1 improved oxidative stress during the aging process via the gut-liver-brain axis.

Frontiers in microbiology·2026
Same author

Integrated Single-Cell Virtual Knockout and Machine Learning Analyses Reveal a Protective Role of CKAP2 in Gastric Cancer.

Molecules (Basel, Switzerland)·2026
Same author

Development and characterization of a 1-2 MeV electron beam platform with magnetic focusing and steering for shallow high-dose-rate irradiation.

Physics in medicine and biology·2026
Same author

Development and validation of a predictive model for postoperative complications in thymoma patients.

Journal of cardiothoracic surgery·2026
Same journal

Correction: Yang et al. Microstructural Characteristics of High-Pressure Die Casting with High Strength-Ductility Synergy Properties: A Review. <i>Materials</i> 2023, <i>16</i>, 1954.

Materials (Basel, Switzerland)·2026
Same journal

Effect of La and Ce Microalloying on the Corrosion Resistance of 0.4Sb Low-Alloy Steel in a Harsh Marine Atmospheric Environment.

Materials (Basel, Switzerland)·2026
Same journal

High-Temperature Properties of Magnesium Ammonium Phosphate Cement Modified with Gold Tailings.

Materials (Basel, Switzerland)·2026
Same journal

A Study on the Evolution of Intermetallic Phase Microstructure and High-Temperature Creep Behavior in Mg-8.0Al-1.0Nd-1.5Gd-Mn Alloys.

Materials (Basel, Switzerland)·2026
Same journal

Material-Driven Clinical Complications in Mechanical Circulatory Support: From Blood-Material Interactions to Device-Related Adverse Events.

Materials (Basel, Switzerland)·2026
Same journal

Influence of Final Irrigation on Calcium Silicate-Based Sealer Dentinal Tubular Penetration: A Systematic Review.

Materials (Basel, Switzerland)·2026
查看所有相关文章

相关实验视频

Updated: Sep 13, 2025

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
10:22

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements

Published on: September 7, 2019

8.4K

一种修改的双温度校准方法和辐射度测量装置.

Shufang He1, Shuai Li1,2, Caihong Dai1

  • 1Division of Optical Metrology, National Institute of Metrology, Beijing 100029, China.

Materials (Basel, Switzerland)
|July 30, 2025
PubMed
概括
此摘要是机器生成的。

本研究引入了一种经过修改的双温度校准方法,用于准确测量红外辐射样本的辐射率. 新的方法消除了对参考黑体的需求,简化了这个过程.

关键词:
背景辐射 背景辐射直接方法是直接方法.测量排放率的测量方法间接方法是间接的方法.材料的红外辐射的材料的红外辐射.修改的两温度校准方法.

更多相关视频

Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
09:18

Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident

Published on: December 14, 2017

10.5K
Fabrication and Testing of Photonic Thermometers
08:44

Fabrication and Testing of Photonic Thermometers

Published on: October 24, 2018

5.9K

相关实验视频

Last Updated: Sep 13, 2025

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
10:22

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements

Published on: September 7, 2019

8.4K
Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
09:18

Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident

Published on: December 14, 2017

10.5K
Fabrication and Testing of Photonic Thermometers
08:44

Fabrication and Testing of Photonic Thermometers

Published on: October 24, 2018

5.9K

科学领域:

  • 计量学 计量学 计量学
  • 红外热像图 (Infrared Thermography) 是一种红外热像图.
  • 材料科学 材料科学 材料科学

背景情况:

  • 精确测量红外辐射样本的辐射率至关重要.
  • 现有的多温度或两温度校准方法依赖于参考黑体,并假定温度独立的背景辐射,这在实践中往往不是真的.

研究的目的:

  • 开发一种经过修改的双温度校准方法和设备,在没有参考黑体的情况下准确测量辐射率.
  • 为了克服以前的方法的局限性,背景辐射取决于温度.

主要方法:

  • 提出了一种修改后的双温度校准方法,在很短的间隔内设置两个温度点.
  • 该方法利用的近似是,在这两个温度下,样品和背景辐射的发射率是相似的.
  • 建造了一个实验设施,用于 (8~14) 微米范围的测量.

主要成果:

  • 在60°C和85°C的温度下,对0.100,0.500和0.900左右的辐射率的样本进行测量.
  • 据报道,不同发射率样本的相对扩展不确定性在85°C时低至1.5%和1.2%.
  • 实验结果显示与其他已建立的测量技术一致.

结论:

  • 开发的修改后的双温度校准方法对于准确的排放性测量是有效的.
  • 这种方法消除了对参考黑体的需求,简化了实际应用.
  • 该技术可能适用于温度不敏感的辐射率的样品.