相关实验视频
Updated: Sep 13, 2025

08:44
Fabrication and Testing of Photonic Thermometers
Published on: October 24, 2018
5.9K
使用嵌入式温度传感器来检测包装改
Geoffrey Chancel1, Julien Toulemont2, Frederick Mailly1
1LIRMM, University of Montpellier, 34095 Montpellier, France.
Sensors (Basel, Switzerland)
|July 30, 2025
概括
本研究介绍了一种负担得起的方法,用于在电源启动时验证集成电路 (IC) 包的完整性. 它使用内置的热传感器间接测量散热,提高硬件安全性.
科学领域:
- 电气工程 电气工程
- 计算机工程 计算机工程
- 硬件安全 硬件安全
背景情况:
- 集成电路 (IC) 面临着重大安全威胁,包括需要删除包的半侵入性攻击.
- 验证IC包的物理完整性至关重要,但研究不足.
- 现有的安全措施往往忽略了物理包的漏洞.
研究的目的:
- 为验证集成电路组件完整性提供一种可访问和有效的解决方案.
- 开发一种方法,在最早的阶段 (power-up) 检测未经授权的包装改.
- 为了利用现有的芯片上组件进行安全验证.
主要方法:
- 使用IC固有的散热特性的一种间接测量技术.
- 热传感器的集成,通常在现代IC中发现,用于数据采集.
- 一个启动验证协议,用于在完全运行之前评估包完整性.
主要成果:
- 证明了使用散热用于包装完整性检查的可行性.
- 拟议的方法具有成本效益,依赖于现有的IC特性.
- 通过异常的热信号成功检测到模拟的包装改.
结论:
- 开发的Power-up验证方法提供了一种实用的方法,可以增强IC安全性,防止半侵入性攻击.
- 使用嵌入式热传感器提供了一种非侵入性和负担得起的手段,以确保包装完整性.
- 这项研究通过专注于物理包验证来解决硬件安全方面的关键差距.
相关概念视频
Assessing Body Temperature - Oral
837
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
837
Equipments Used to Measure Body Temperature
1.2K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.2K
Assessing Body Temperature - Temporal Artery
672
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
672
Assessing Body Temperature - Tympanic membrane
669
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
669
Physical Methods for Controlling Microbial Growth: Temperature
251
Heat is a widely used method to control microbial growth by targeting and denaturing cellular proteins, thereby killing or inactivating microbes. This method's effectiveness is quantified using parameters such as the thermal death point (TDP), thermal death time (TDT), and decimal reduction time (D value). TDP represents the lowest temperature at which all microorganisms in a liquid suspension are eliminated within 10 minutes, whereas TDT is the time necessary to achieve sterilization at a...
251
Temperature Measurement Sites
2.2K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
2.2K