一个混合光纤探测器,用于同时测量尘埃度和温度
Chuanwei Zhai1,2, Li Xiong2,3
1China Academy of Safety Science and Technology, Beijing 100012, China.
Sensors (Basel, Switzerland)
|July 30, 2025
概括
这项研究引入了一种新的混合光纤探测器,用于同时测量尘埃度和温度. 这种内在安全的设备提供了双参数传感和网络监控的潜力.
科学领域:
- 光学传感技术的技术.
- 环境监测仪器仪表环境监测仪器仪表
背景情况:
- 现有的尘埃度传感器缺乏双参数测量能力和内在安全性.
- 准确的同时测量尘埃度和温度对于工业安全和环境监测至关重要.
研究的目的:
- 开发一种混合光纤探测器,用于同时测量尘埃度和温度.
- 为了利用纤维布拉格格 (FBG) 和光灭绝原理来增强传感.
主要方法:
- 设计了一个混合探测器,结合了FBG和灭光.
- 通过监测FBG反射频谱强度 (尘埃) 和波长 (温度) 来实现的同时测量.
- 两个光学聚合仪和一个FBG作为关键传感元件.
主要成果:
- 探测器证明了同时感测尘埃度和温度,并提供最小的合输出 (±3 pm和±0.1 mW).
- 尘埃度与FBG光强度变化呈指数关系 (适配系数≈0.94).
- 通过对权重方法进行验证,证实了较小的测量偏差.
结论:
- 拟议的混合光纤探测器可以实现内在安全和双参数传感.
- 这项技术为在网络上监测尘埃度和温度提供了一个有前途的解决方案.
- 该探测器提供通过校准和比较分析验证的准确和可靠的测量.
相关概念视频
Gas Chromatography: Types of Detectors-I
620
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
620
Gas Chromatography: Types of Detectors-II
502
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
502
IR Spectrometers
1.5K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.5K
UV–Vis Spectrometers
1.5K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.5K